Journal of clinical medicine

Visual Performance and Patient-Reported Visual Function with Multifocal, Monofocal, and Enhanced Monofocal Intraocular Lenses.

Hadas Ben-Eli, Inbar Wunch, Riki Maroko, Tamar Winnett, Deborah Berrih-Elkouby, Arie L Marcovich

Department of Optometry and Vision Science, Jerusalem Multidisciplinary College, 37 Hanevi'im St., Jerusalem 9101001, Israel. · Department of Ophthalmology, Kaplan Medical Center, Rehovot 7661041, Israel.

Observational · n=84

Key points

From the paper's conclusion
  • Overall patient-reported visual function did not differ among the groups, and findings from the additional intermediate-vision questions were exploratory.

Abstract

Objective: The aim of the study was to compare visual performance and patient-reported visual function among the enhanced monofocal TECNIS Eyhance, conventional monofocal Sensar, and multifocal Synergy intraocular lenses (IOLs) (Johnson & Johnson Surgical Vision, Inc., Santa Ana, CA, USA). Methods: This prospective comparative observational study included patients assessed after cataract surgery with Eyhance, Sensar, or Synergy implantation. Uncorrected and corrected visual acuity were measured at distance, intermediate, and near, and contrast sensitivity was assessed using the Pelli-Robson chart. Participants completed the validated Visual Function Index (VF-14) and three nonvalidated exploratory questions addressing unaided intermediate vision. Eye-level outcomes were analyzed using linear mixed-effects models accounting for fellow-eye correlation and adjusted for age and preoperative spherical equivalent. The VF-14 was analyzed once per participant. Results: Fifty-two participants were enrolled, of whom 51 contributed 84 eligible eyes to the analysis: 40 Eyhance, 26 Synergy, and 18 Sensar eyes. Among the 51 analyzed participants, 31 (60.8%) were women. Mean age of participants was 69.98 ± 7.90 years, with an age range of 48-85 years. Adjusted uncorrected distance visual acuity did not differ among the IOL groups (p = 0.994). Synergy provided better uncorrected intermediate and near visual acuity than Eyhance and Sensar (overall p < 0.001 for both), whereas Eyhance and Sensar did not differ. Corrected visual acuity did not differ significantly among the groups at any distance. Contrast sensitivity differed at distance (p = 0.007) and near (p = 0.011); Synergy had lower values than both monofocal-type IOLs, whereas Eyhance and Sensar were comparable. Adjusted VF-14 scores did not differ among the groups (p = 0.451). Exploratory intermediate-vision responses favored Synergy but demonstrated a pronounced ceiling effect. Conclusions: All three IOLs provided comparable uncorrected distance visual acuity. Synergy was associated with better unaided intermediate and near visual acuity but lower contrast sensitivity, whereas Eyhance showed no objective advantage over Sensar. Overall patient-reported visual function did not differ among the groups, and findings from the additional intermediate-vision questions were exploratory.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers