Comparing Visual Outcomes Between Two Extended Depth-of-Focus Intraocular Lenses in an Asian Population.
Jessica Q H Choo, Peng Y Tan, Younian Yang, Melissa H Y Wong
Singapore National Eye Centre, 11 Third Hospital Ave, Singapore 168751, Singapore.
Key points
From the paper's conclusion- Background/Objectives: To compare the visual outcomes between two extended depth-of-focus intraocular lenses (EDOF IOLs) in an Asian population.
Abstract
Background/Objectives: To compare the visual outcomes between two extended depth-of-focus intraocular lenses (EDOF IOLs) in an Asian population. Methods: This retrospective single-center study included patients with senile cataract undergoing cataract surgery with implantation of either TECNIS PureSee or AcrySof IQ Vivity IOL. Visual and refractive outcomes such as visual acuity (VA), manifest refraction, and mean refractive spherical equivalent were compared up to post-operative month 6. Contrast sensitivity and defocus curves were evaluated monocularly, as well as binocularly if both eyes had the same IOL implanted. Results: Forty-nine eyes were evaluated-24 implanted with PureSee and 25 implanted with AcrySof IQ Vivity. The follow-up period was 6.4 ± 1.1 months in the PureSee group and 6.4 ± 1.0 months in the Vivity group (p = 1.0). There was no significant difference in postoperative visual outcomes at postoperative month 1 or 6. At post-operative month 6, unaided distance VA was 0.06 ± 0.10 and 0.08 ± 0.14 in the PureSee and Vivity groups, respectively (p = 0.519); unaided intermediate VA was 0.21 ± 0.05 and 0.18 ± 0.09, respectively (p = 0.192); and unaided near VA was 0.38 ± 0.12 and 0.38 ± 0.12, respectively (p = 0.842). Defocus and contrast sensitivity performance were broadly similar, except for Vivity's defocus being marginally better at 66 cm intermediate distance. At post-operative month 1, 69.2% of Vivity patients (n = 13) and 75.0% of PureSee patients (n = 4) denied haloes or glare. Conclusions: Both EDOF IOLs demonstrated comparable visual performances.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of U.S. FDA premarket approval studies between two non-diffractive extended depth of focus lenses (AcrySof IQ Vivity versus TECNIS PureSee).Medical hypothesis, discovery & innovation ophthalmology journal · 2026
- Comparison of 12-Month Visual Outcomes and Patient-Reported Measures between the BVI Isopure Enhanced Monofocal IOL and the AcrySof IQ Monofocal IOL.Korean journal of ophthalmology : KJO · 2026
- A Comparative Study of the Visual Outcomes of Two Common Diffractive Trifocal Intraocular Lenses in a Matched Cohort.Cureus · 2026
- Visual Performance and Patient-Reported Visual Function with Multifocal, Monofocal, and Enhanced Monofocal Intraocular Lenses.Journal of clinical medicine · 2026
- Visual performance and quality outcomes after implantation of hybrid multifocal-extended depth of focus intraocular lenses.International journal of ophthalmology · 2026
- Comparison of clinical outcomes of trifocal versus extended depth of focus intraocular lenses: meta-analysis of randomized controlled trials.BMC ophthalmology · 2026