Intra-individual comparison of two non-diffractive enhanced monofocal intraocular lenses.
Andreas Rotter, Manuel Ruiss, Johannes Zeilinger, Stefan Georgiev, Caroline Pilwachs, Oliver Findl
Hanusch Hospital, Vienna, Austria. · Vienna Institute for Research in Ocular Surgery (VIROS), Karl Landsteiner Institute, Hanusch Hospital, Vienna, Austria.
Key points
From the paper's conclusion- Apart from isolated secondary outcomes, no significant differences in visual performance were detected between the Evolux and the well-established Tecnis Eyhance IOL in an intra-individual setting, although equivalence was not formally tested.
Abstract
PURPOSE: To intra-individually compare the clinical visual performance of a recently introduced and an established enhanced monofocal intraocular lens (IOL). SETTING: Vienna Institute for Research in Ocular Surgery, Hanusch Hospital, Vienna, Austria. DESIGN: Single-center, randomized, double-masked trial. METHODS: Patients received the Evolux IOL (SIFI S.p.A.) in one eye and the Tecnis Eyhance IOL (Johnson & Johnson Vision) in the contralateral eye, targeting emmetropia. Primary endpoint was uncorrected intermediate visual acuity (UIVA) at 66 cm. Secondary outcomes included monocular uncorrected and distance corrected visual acuity at far (4 m) (UDVA, CDVA), intermediate (66 cm) (DCIVA) and near (40 cm) (UNVA, DCNVA), as well as refractive predictability, contrast sensitivity, halometry and a monocular vision questionnaire. RESULTS: 30 patients (60 eyes) were included. At 3 months, mean UDVA, UIVA, and UNVA did not differ significantly between the Evolux and Tecnis Eyhance IOLs: 0.00 ±0.11 vs 0.02 ±0.10, 0.15 ±0.14 vs 0.16 ±0.15 and 0.32 ±0.16 vs 0.30 ±0.17 logMAR (all P > 0.05). For UIVA, the mean paired difference was -0.01 logMAR (95% confidence interval, -0.06 to 0.04). At 1 month, UNVA was better with the Tecnis Eyhance (P = 0.035), but not at 3 months. Photopic contrast sensitivity at 18 cycles per degree favored the Tecnis Eyhance (P = 0.018), whereas no other secondary outcome differed significantly. CONCLUSIONS: Apart from isolated secondary outcomes, no significant differences in visual performance were detected between the Evolux and the well-established Tecnis Eyhance IOL in an intra-individual setting, although equivalence was not formally tested.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Pupil Size Associations and Refractive Error Tolerance in Enhanced Monofocal Intraocular Lenses With Different Central Optic Designs.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Comparison of visual outcomes and optical performance between Eyhance ICB00 and Lentis Comfort LS-313 MF15 intraocular lenses.International journal of ophthalmology · 2026
- Visual Performance and Patient-Reported Visual Function with Multifocal, Monofocal, and Enhanced Monofocal Intraocular Lenses.Journal of clinical medicine · 2026
- Comparative Clinical Outcomes Between Successive Generations of Liberty Trifocal Intraocular Lenses.Journal of clinical medicine · 2026
- Clinical and refractive outcomes of bilateral enhanced monofocal intraocular lens implantation with targeted mini-monovision.BMC ophthalmology · 2026
- Visual performance of a refractive extended depth of field intraocular lens in monovision and emmetropic settings.American journal of ophthalmology · 2026