Visual Performance of a Novel Intraocular Lens With Higher-Order Aspheric Design Optimized for Intermediate Vision.
Nuria Garzón, Pedro Arriola-Villalobos, Natalia Hormigo-Márquez, María García-Montero, César Albarrán-Diego
Department Optometry and Vision, Complutense University of Madrid, Madrid, Spain. · Servicio de Oftalmología, Hospital Clínico San Carlos, Departamento de Inmunología, Oftalmología y ORL, Facultad de Medicina, Universidad Complutense de Madrid, IdISSC, Madrid, Spain.
Key points
From the paper's conclusion- This enhanced monofocal IOL provided excellent distance visual acuity, functional intermediate vision, preserved contrast sensitivity, and limited overall dependence on pupil size.
Abstract
PURPOSE: To evaluate the visual performance of an enhanced monofocal intraocular lens (IOL) and the influence of pupil size. METHODS: This prospective, observational, single-center study was conducted at Hospital Clínico San Carlos (Madrid, Spain). Patients undergoing cataract surgery with an enhanced monofocal IOL (enVista Aspire; Bausch + Lomb, Inc) were included. Postoperative monocular assessments were performed under photopic conditions at 3 months. Uncorrected and corrected visual acuity were measured at distance (4 m), intermediate (66 cm), and near (40 cm). Defocus curves and photopic contrast sensitivity were assessed, and automated refraction was compared with manifest refraction. Defocus curves were analyzed using area-under-the-curve and depth-of-focus metrics, and visual outcomes were stratified by photopic pupil size (<3.5 vs ⩾3.5 mm). Agreement between autorefractometry and subjective refraction was evaluated using Bland-Altman analysis. RESULTS: Twenty-two eyes of 22 patients were included. Mean postoperative uncorrected and corrected distance visual acuity was 0.09 ± 0.12 and -0.02 ± 0.07 logarithm of the minimum angle of resolution (logMAR), respectively; 19 eyes (86.4%) achieved uncorrected distance visual acuity of 0.2 logMAR or better and all eyes achieved corrected distance visual acuity of 0.1 logMAR or better. Mean corrected intermediate and near visual acuity were 0.32 ± 0.13 and 0.52 ± 0.18 logMAR, respectively. Contrast sensitivity showed a normal band-pass profile. Agreement between autorefractometry and manifest refraction showed a small mean bias for spherical equivalent (+0.08 diopters). Pupil size showed no overall main effect on defocus curves or contrast sensitivity, although a defocus-specific interaction was observed. CONCLUSIONS: This enhanced monofocal IOL provided excellent distance visual acuity, functional intermediate vision, preserved contrast sensitivity, and limited overall dependence on pupil size.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Pupil Size Associations and Refractive Error Tolerance in Enhanced Monofocal Intraocular Lenses With Different Central Optic Designs.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Prospective Evaluation Of Visual Performance Of A Novel Partial Depth Of Field Intraocular Lens Using A Monovision Strategy.Journal of cataract and refractive surgery · 2026
- Intermediate and near vision outcomes with an advanced monofocal aspheric Swiss Phob intraocular lens.Indian journal of ophthalmology · 2026
- Binocular intermediate vision enhancement without compromising optical quality using a SwissPhob enhanced monofocal intraocular lens.Indian journal of ophthalmology · 2026
- Comparison of 12-Month Visual Outcomes and Patient-Reported Measures between the BVI Isopure Enhanced Monofocal IOL and the AcrySof IQ Monofocal IOL.Korean journal of ophthalmology : KJO · 2026
- Real-World Experience with Enhanced Monofocal Intraocular Lenses Following Cataract Surgery: A Multicenter Retrospective Case Series.Ophthalmology and therapy · 2026