Comparison of visual outcomes and optical performance between Eyhance ICB00 and Lentis Comfort LS-313 MF15 intraocular lenses.
Minji Woo, Youngsub Eom, Seul Ki Yang, Jinhwan Park, Youngbin Song, Hyun Sun Jeon, Dong Hyun Kim, Seong-Jae Kim,
Department of Ophthalmology, Korea University College of Medicine, Seoul 136-702, Republic of Korea. · Satellite System 3 Team, Hanwha Systems Co., Ltd., Yongin-si, Gyeonggi-do 15355, Republic of Korea.
Key points
From the paper's conclusion- The LS-313 MF15 IOL demonstrates a significant advantage over the ICB00 IOL regarding intermediate and near visual acuity. The LS-313 MF15 exhibits superior optical performance on bench testing, suggesting better functional outcomes for patients requiring a broader vision range.
Abstract
AIM: To compare the postoperative visual outcomes and optical performance of the Eyhance ICB00 and Lentis Comfort LS-313 MF15 intraocular lenses (IOLs). METHODS: Patients who underwent phacoemulsification with bilateral IOL implantation, receiving the ICB00 IOL in one eye and the LS-313 MF15 IOL in the fellow eye, were enrolled in this retrospective study. Postoperative visual acuities, including corrected distance visual acuity (CDVA) and intermediate and near visual acuities, and monocular and binocular defocus curves were measured. Postoperative incidences of visual disturbances were also assessed. Optical bench testing evaluated the modulation transfer function (MTF) values at various defocus levels. RESULTS: The study included 52 eyes from 26 patients (16 females; 61.5%) who underwent ICB00 IOL implantation in one eye (26 eyes) and LS-313 MF15 IOL implantation in the opposite eye (26 eyes). The mean patient age was 69.2±8.4y (range, 55-84y). Both IOLs achieved excellent postoperative CDVA of 20/20 or better without significant differences between groups (88.5% vs 92.3%). Intermediate and near visual acuity were better in the LS-313 MF15 group compared with the ICB00 group, whereas the frequency of glare, starbursts, and halos was comparable between groups. The binocular defocus curve demonstrated better visual performance across defocus levels compared with both monocular curves, and the LS-313 MF15 group showed better visual acuity than the ICB00 group at negative defocus levels. Optical bench testing demonstrated that the LS-313 MF15 IOL provided higher MTF values at negative defocus levels compared with the ICB00 IOL. CONCLUSION: The LS-313 MF15 IOL demonstrates a significant advantage over the ICB00 IOL regarding intermediate and near visual acuity. The LS-313 MF15 exhibits superior optical performance on bench testing, suggesting better functional outcomes for patients requiring a broader vision range.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Intra-individual comparison of two non-diffractive enhanced monofocal intraocular lenses.Journal of cataract and refractive surgery · 2026
- Visual Performance and Patient-Reported Visual Function with Multifocal, Monofocal, and Enhanced Monofocal Intraocular Lenses.Journal of clinical medicine · 2026
- Comparative Clinical Outcomes Between Successive Generations of Liberty Trifocal Intraocular Lenses.Journal of clinical medicine · 2026
- Pupil Size Associations and Refractive Error Tolerance in Enhanced Monofocal Intraocular Lenses With Different Central Optic Designs.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Three-Year Functional Vision, Longitudinal Refractive Outcomes, and Patient-Reported Outcomes After Bilateral Implantation of the Extend Bessel-Optics Intraocular Lens: An Independent Real-World Ambispective Study.Medicina (Kaunas, Lithuania) · 2026
- Comparing Visual Outcomes Between Two Extended Depth-of-Focus Intraocular Lenses in an Asian Population.Diagnostics (Basel, Switzerland) · 2026