Proton treatment-plan dose verification with a DPM-based Monte Carlo engine.

Aimee L McNamara, Daniel O'Brien, Alan Nelson

Radformation Inc., New York, NY, United States.

Computational

Key points

From the paper's conclusion
  • We use a pre-release version of the commercial RadMonteCarlo, a multithreaded CPU-based proton Monte Carlo engine built on a dose planning method (DPM) framework for independent treatment-plan recalculation.

Abstract

INTRODUCTION: Independent proton dose verification requires a calculation pathway that is accurate enough to identify clinically relevant discrepancies while remaining practical to commission and operate. We use a pre-release version of the commercial RadMonteCarlo, a multithreaded CPU-based proton Monte Carlo engine built on a dose planning method (DPM) framework for independent treatment-plan recalculation. In this study, we evaluate the sensitivity of RadMonteCarlo to the conversion of CT Hounsfield units (HU) to relative stopping power (RSP). METHODS: RadMonteCarlo was commissioned from integrated depth-dose (IDD) curves, spot profiles, and absolute-output data for a pencil beam scanning proton system. Three HU-to-RSP assignments were evaluated: a density-derived parameterization, a Bethe-Bloch-based calculation, and a Schneider stoichiometric tissue model. Four anonymized clinical plans (prostate, bladder, lung, and brain) were recalculated. RadMonteCarlo dose was compared with the RayStation Monte Carlo dose, using three-dimensional gamma criteria of 3%/3 mm and 2%/ 2 mm. RadMonteCarlo distributions were also compared directly to isolate RSP sensitivity from TPS agreement. RESULTS: The commissioned fits achieved a mean R² of 0.9998, and re-simulated R80 values agreed with the measurements within 1 mm (mean difference +0.39 mm). All 12 clinical plan-RSP comparisons met the specified 95% criterion at 3%/3 mm. In direct RSP model comparisons, target mean-dose differences ranged from-1.15% to +1.20%, distal R80 shifts along the beam axes ranged from-0.3 to +1.9 mm, and the 95th-percentile absolute voxelwise dose difference ranged from 1.8% to 4.1%. DISCUSSION: These controlled comparisons demonstrate that HU-to-RSP selection produces localized, anatomy- and beam-path- dependent changes in the individual cases examined. RadMonteCarlo therefore provides a stable independent recalculation framework in which calibration-driven effects can be identified and interpreted separately from transport or source-model differences.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers