Monte Carlo intercomparison of TG-43 dosimetric parameters for clinical192Ir and125I brachytherapy sources.
Lucas Fabrício de Araújo, Asif Amin, Adriano Sabino, Telma Fonseca
Department of Nuclear Engineering, Universidade Federal de Minas Gerais, Avenida Presidente Antônio Carlos, 6627, Belo Horizonte, 31270-901, Brazil. · School of Pharmacy, Federal University of Minas Gerais, Avenida Presidente Antônio Carlos, 6627, bairro Pampulha, Belo Horizonte, 31270-901, Brazil.
Key points
From the paper's conclusion- Overall, this study validates the accuracy and reliability of the investigated MC codes for high-precision brachytherapy dosimetry, establishing a robust computational baseline for future applications in patient-specific treatment planning and radiosensitization studies.
Abstract
Accurate dose calculation is essential in brachytherapy and frequently relies on Monte Carlo (MC) simulations for the determination of TG-43 dosimetric parameters. This study presents a comprehensive intercomparison of three general-purpose MC codes, MCNP6.2, TOPAS 3.9, and PHITS 3.341, for the evaluation of the geometry function, radial dose function, and anisotropy function of the microSelectron-HDR v2192Ir source and the Theragenics-AgX100125I seed. The simulations employed the complete photon emission spectra recommended by ICRP 107 and the datasets were rigorously benchmarked against established consensus literature, and a fifth-order polynomial fitting was applied to the radial dose function data. The results demonstrated excellent overall agreement among the three MC codes and the reference datasets. The polynomial fitting accurately reproduced the radial dose distributions, with deviations remaining predominantly below the recommended 2 % limit within clinically relevant radial intervals. Nevertheless, larger discrepancies were observed for the low-energy125I source at extended distances, emphasizing the greater sensitivity of low-energy photon transport and attenuation effects compared with the more stable behavior observed for the192Ir source. Overall, this study validates the accuracy and reliability of the investigated MC codes for high-precision brachytherapy dosimetry, establishing a robust computational baseline for future applications in patient-specific treatment planning and radiosensitization studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical test cases for commissioning, QA, and benchmarking of model‐based dose calculation algorithms in¹ ⁹² Ir HDR gynecologic tandem and ring brachytherapyMedical Physics · 2026
- Dosimetric Characterization of the 125I BEBIG IsoSeed I25.S06 source Using Python-Based Calculations.Health physics · 2026
- Distance-dependent influence of scoring voxel size on Monte Carlo dosimetry of an iridium-192 HDR brachytherapy sourceEPJ Web of Conferences · 2026
- Investigation of TG-43 dose calculation algorithm for volumetric HDR Brachytherapy using Monte Carlo simulation in TOPAS.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Dosimetric comparison of HDR Co-60 and Ir-192 brachytherapy sources by model-based dose calculation algorithms and its clinical implication in different brachytherapy sites and techniques.Brachytherapy · 2026
- Dosimetric and therapeutic effectiveness of high-dose-rate radionuclide sources in breast cancer brachytherapy: A systematic review.Brachytherapy · 2026