Aortic valve calcification and one-year paravalvular leak after transcatheter aortic valve replacement: limited role of asymmetry.
Pragati Basera, Roya Anahita Mousavi, Chisom Enwere, Minel Soroa, Edgar Argulian, Leila Alizadeh, Marcos Ferrandez-Escarabajal, Carlo Mannina,
Department of Internal Medicine, Mount Sinai Morningside/West, Icahn School of Medicine at Mount Sinai, New York, New York. · Division of Cardiology, Mount Sinai Fuster Heart Hospital, Icahn School of Medicine at Mount Sinai, New York, New York.
Key points
From the paper's conclusion- Total AVC independently predicts mild or greater PVL at 1 year after TAVR, whereas leaflet-specific asymmetry and valve type provide no additional predictive value.
Abstract
OBJECTIVES: Paravalvular leak (PVL) is a significant complication after transcatheter aortic valve replacement (TAVR). Although total aortic valve calcification (AVC) burden and self-expandable valves are predictors of PVL, the impact of leaflet-specific AVC asymmetry remains uncertain. The authors evaluated the association between AVC asymmetry and mild or greater PVL at 1 year after TAVR and its interaction with valve type. METHODS: Patients undergoing TAVR between January 2022 and May 2025 with preprocedural noncontrast cardiac computed tomography and 1-year transthoracic echocardiography were included. Asymmetric AVC was defined as greater than 50% of total AVC on a single cusp. RESULTS: Among 530 patients (mean age, 79 ± 8 years; 45.5% female), 130 (24.5%) had mild or greater PVL at 1 year. Total AVC was higher in women (1747 vs 1125 AU; P less than .001) and men (2612 vs 2063 AU; P less than .001) with mild or greater PVL, with greater calcification across all cusps. AVC asymmetry was comparable between PVL and non-PVL groups (33.1% vs 41.4%; P = .093). Total AVC independently predicted PVL (adjusted odds ratio [OR], 1.036 per 100 AU; P < .001), whereas asymmetry did not (adjusted OR, 0.912; P = .681). No significant interaction occurred between valve type, AVC asymmetry, and PVL (P = .224). CONCLUSIONS: Total AVC independently predicts mild or greater PVL at 1 year after TAVR, whereas leaflet-specific asymmetry and valve type provide no additional predictive value.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Association between annular eccentricity and initial post-deployment paravalvular leak before corrective maneuvers in bicuspid aortic valve patients undergoing self-expanding transcatheter aortic valve replacement: a single-center retrospective study.Frontiers in cardiovascular medicine · 2026
- Lower Aortic Valve Calcification in TAVI Candidates with a Pre-Existing Permanent PacemakerJournal of Clinical Medicine · 2026
- Long-term impact of prosthesis-patient mismatch after transcatheter aortic valve replacement.Cardiovascular intervention and therapeutics · 2026
- Paravalvular Leak After Transcatheter Aortic Valve Implantation: Haemodynamic Consequences, Clinical Impact, and Contemporary Assessment.Journal of cardiovascular development and disease · 2026
- Mid-term impact of prosthesis-patient mismatch after transcatheter aortic valve implantation using a self-expanding or balloon-expandable transcatheter heart valveEuropean Heart Journal · 2026
- Preoperative AI-ECG analysis predicts paravalvular leak after transcatheter aortic valve replacementEuropean Heart Journal · 2026