Key points

From the paper's conclusion
  • Total AVC independently predicts mild or greater PVL at 1 year after TAVR, whereas leaflet-specific asymmetry and valve type provide no additional predictive value.

Abstract

OBJECTIVES: Paravalvular leak (PVL) is a significant complication after transcatheter aortic valve replacement (TAVR). Although total aortic valve calcification (AVC) burden and self-expandable valves are predictors of PVL, the impact of leaflet-specific AVC asymmetry remains uncertain. The authors evaluated the association between AVC asymmetry and mild or greater PVL at 1 year after TAVR and its interaction with valve type. METHODS: Patients undergoing TAVR between January 2022 and May 2025 with preprocedural noncontrast cardiac computed tomography and 1-year transthoracic echocardiography were included. Asymmetric AVC was defined as greater than 50% of total AVC on a single cusp. RESULTS: Among 530 patients (mean age, 79 ± 8 years; 45.5% female), 130 (24.5%) had mild or greater PVL at 1 year. Total AVC was higher in women (1747 vs 1125 AU; P less than .001) and men (2612 vs 2063 AU; P less than .001) with mild or greater PVL, with greater calcification across all cusps. AVC asymmetry was comparable between PVL and non-PVL groups (33.1% vs 41.4%; P = .093). Total AVC independently predicted PVL (adjusted odds ratio [OR], 1.036 per 100 AU; P < .001), whereas asymmetry did not (adjusted OR, 0.912; P = .681). No significant interaction occurred between valve type, AVC asymmetry, and PVL (P = .224). CONCLUSIONS: Total AVC independently predicts mild or greater PVL at 1 year after TAVR, whereas leaflet-specific asymmetry and valve type provide no additional predictive value.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers