Paravalvular Leak After Transcatheter Aortic Valve Implantation: Haemodynamic Consequences, Clinical Impact, and Contemporary Assessment.
Mohamed Ali, Omran Abukhalaf, Mohammad Alkhalil
Cardiothoracic Centre, Freeman Hospital, Newcastle-upon-Tyne NE7 7DN, UK.
Key points
From the paper's conclusion- Particular emphasis is placed on the limitations of pressure-based assessment and the need for a patient-specific, flow-oriented approach aligned with contemporary endpoint definitions such as those proposed by VARC-3.
Abstract
Paravalvular leak (PVL) remains an important limitation of transcatheter aortic valve implantation (TAVI), despite major advances in prosthesis design, imaging guidance, and implantation technique. Although the incidence of moderate and severe PVL has substantially declined with newer-generation valves, mild PVL continues to be frequently observed in contemporary practice and is increasingly recognised as clinically relevant. Multiple studies have demonstrated an association between even mild PVL and adverse outcomes, particularly heart failure (HF) hospitalisation, suggesting that conventional grading systems may underestimate its true haemodynamic burden. Beyond simple regurgitant volume, PVL is characterised by eccentric high-velocity flow, turbulence, impaired pressure recovery, and reduced haemodynamic efficiency. These effects may be particularly important in vulnerable phenotypes such as patients with heart failure with preserved ejection fraction (HFpEF), concentric left ventricular hypertrophy, or low-flow states, in whom small regurgitant volumes can result in disproportionate increases in filling pressures and symptomatic deterioration. This review summarises contemporary evidence regarding the prevalence, diagnosis, haemodynamic impact, and clinical consequences of PVL after TAVI. Differences across valve platforms, predictors of PVL, and current management strategies are also discussed. Particular emphasis is placed on the limitations of pressure-based assessment and the need for a patient-specific, flow-oriented approach aligned with contemporary endpoint definitions such as those proposed by VARC-3.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative prognostic impact of paravalvular leak versus permanent pacemaker implantation after transcatheter aortic valve implantation without reduced ejection fraction patientsEuropean Heart Journal · 2026
- Prognostic value of algorithm-based invasive haemodynamic assessment of paravalvular regurgitation after transcatheter aortic valve replacement with self-expanding devices-the APPOSE registry.European heart journal. Valvular and structural heart disease · 2026
- Mortality in patients with mild and moderate paravalvular leakage after transcatheter aortic valve implantationEuropean Heart Journal · 2026
- Prognostic Impact of Paravalvular Regurgitation in Patients With Severe Low-Flow, Low-Gradient Aortic Stenosis Undergoing TAVR.JACC. Cardiovascular interventions · 2026
- Aortic valve calcification and one-year paravalvular leak after transcatheter aortic valve replacement: limited role of asymmetry.The Journal of invasive cardiology · 2026
- Prosthesis–Patient Mismatch Following Aortic Valve Replacement—A Comprehensive ReviewJournal of Clinical Medicine · 2025