Association between annular eccentricity and initial post-deployment paravalvular leak before corrective maneuvers in bicuspid aortic valve patients undergoing self-expanding transcatheter aortic valve replacement: a single-center retrospective study.
Chen Cui, Zhanjun Qu, Ze Zhao, Weili Liu, Lei Jiang
Department of Cardiovascular Surgery, Affiliated Hospital of Qingdao University, Qingdao, China. · Department of Radiology, Qingdao Eighth People's Hospital, Qingdao, China.
Key points
From the paper's conclusion- In BAV patients undergoing TAVR with the first-generation self-expanding VenusA valve, EI ≥0.19 was independently associated with initial post-deployment moderate-or-greater PVL, but its stand-alone and model-level discriminative performance were limited. EI should be considered a supplementary dimension in integrated preprocedural risk assessment rather than an isolated decision-making criterion.
Abstract
OBJECTIVE: The relationship between annular eccentricity and paravalvular leak (PVL) after transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BAV) patients remains insufficiently defined, particularly for Chinese self-expanding valve platforms. This study evaluated the association between the CT-derived eccentricity index (EI) and initial post-deployment moderate-or-greater PVL after self-expanding TAVR in BAV patients. METHODS: We retrospectively analyzed 194 consecutive BAV patients who underwent TAVR with the first-generation self-expanding VenusA valve. The primary endpoint was moderate-or-greater PVL assessed immediately after valve release and before corrective maneuvers such as post-dilatation. EI was measured by two independent observers with excellent interobserver agreement (ICC = 0.943). Multivariable logistic regression, ROC analysis, sensitivity analyses, and bootstrap internal validation were performed. NRI and IDI were analyzed as secondary measures of incremental information. RESULTS: Initial post-deployment moderate-or-greater PVL occurred in 62 patients (32.0%). Although EI was modestly higher in patients with moderate-or-greater PVL than in those with no/mild PVL (median 0.23 [IQR 0.19-0.26] vs. 0.20 [0.17-0.25]; P = 0.005), its stand-alone discrimination was poor (AUC = 0.625; 95% CI 0.539-0.711). After adjustment for clinical and anatomical covariates, EI ≥0.19 remained independently associated with moderate-or-greater PVL (OR = 2.99; 95% CI 1.44-6.23; P = 0.0034), whereas semi-quantitative leaflet calcification and raphe calcification were not. Adding EI increased the C-index only marginally (apparent 0.572 → 0.666; optimism-corrected 0.609), indicating limited overall model discrimination. Predischarge transesophageal echocardiography was available for all 194 patients: moderate-or-greater PVL fell from 62 patients (32.0%) at deployment to only 6 (3.1%) at predischarge, and 57 of the 62 patients with initial moderate-or-greater PVL (91.9%) had regressed to mild or less (paired Wilcoxon signed-rank, P < 0.001), underscoring that initial post-deployment PVL does not equate to clinically relevant residual PVL. CONCLUSION: In BAV patients undergoing TAVR with the first-generation self-expanding VenusA valve, EI ≥0.19 was independently associated with initial post-deployment moderate-or-greater PVL, but its stand-alone and model-level discriminative performance were limited. EI should be considered a supplementary dimension in integrated preprocedural risk assessment rather than an isolated decision-making criterion.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Aortic valve calcification and one-year paravalvular leak after transcatheter aortic valve replacement: limited role of asymmetry.The Journal of invasive cardiology · 2026
- Balloon-expandable valves vs self-expanding valves for transcatheter aortic valve replacement in bicuspid aortic valve stenosis: a meta-analysisEuropean Heart Journal · 2026
- TAVI for Bicuspid Aortic Valve: Addressing Technical Challenges and Optimizing OutcomesJournal of Clinical Medicine · 2025
- Newer-generation balloon-expandable vs. self-expanding transcatheter aortic valves: a propensity score matched analysis.Journal of cardiovascular medicine (Hagerstown, Md.) · 2026
- Preoperative AI-ECG analysis predicts paravalvular leak after transcatheter aortic valve replacementEuropean Heart Journal · 2026