European Heart Journal

Mid-term impact of prosthesis-patient mismatch after transcatheter aortic valve implantation using a self-expanding or balloon-expandable transcatheter heart valve

Y Taniguchi, T Rheude, W K Kim, H Moellmann, A Linke, M Hilker, H Thiele, S Kerber,

Key points

From the paper's conclusion
  • Background The clinical relevance of prosthesis-patient mismatch (PPM) after transcatheter aortic valve implantation (TAVI) remains controversial.

Abstract

Background The clinical relevance of prosthesis-patient mismatch (PPM) after transcatheter aortic valve implantation (TAVI) remains controversial. The aim of this study was to compare the frequency of PPM after TAVI using a self-expanding or a balloon-expandable transcatheter heart valve and to investigate the impact of PPM on clinical outcomes and health-related quality of life measures throughout three years. Methods Patients treated in the SCOPE I trial were stratified according to PPM, which was determined by the indexed effective orifice area (EOAi). All patients were stratified according to the EOAi: moderate PPM was defined as 0.66-0.85 cm2/m2 and severe PPM as ≤0.65 cm2/m2. Outcomes of interest included a composite endpoint integrating both vital status and patient-reported, disease-specific health status, as well as clinical endpoints defined according to VARC-3 criteria. Results A total of 701 patients were included. The frequency of any PPM was 41.9% (moderate 29.7% [208/701]; severe 12.3% [86/701]). Any PPM was more frequent with balloon-expandable prosthesis compared with self-expandable prosthesis (53.5% versus 29.9%, p <0.01). Patients with any PPM had less improvement in patient-reported health status after TAVI throughout three years compared to patients with no PPM (improvement of Kansas City Cardiomyopathy Questionnaire 12 Overall Summary score: +14.6 [3.1-32.3] vs. +21.4 [8.3-38.0], p=0.04). The rate of VARC-3 unfavorable outcome was comparable in patients with any and no PPM (16.5% vs. 18.4%, p=0.53). All-cause mortality at three years was not significantly increased in patients with any PPM (24.8% vs. 21.1%, Hazard Ratio 1.14, p=0.13). Conclusions PPM was frequently observed, especially in TAVI patients treated with balloon expandable valves. Patients with any PPM after TAVI had less improvement in patient-reported health status, without impact on all-cause mortality rates during extended follow-up.For image description, please refer to the figure legend and surrounding text.For image description, please refer to the figure legend and surrounding text.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers