Long-term impact of prosthesis-patient mismatch after transcatheter aortic valve replacement.
Shingo Sakata, Kentaro Hayashida, Ryo Arita, Tomonari Moriizumi, Juri Iwata, Akiyoshi Kajino, Toshinobu Ryuzaki, Keitaro Shinada,
Department of Cardiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan. · Department of Cardiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan. khayashidamd@gmail.com.
Key points
From the paper's conclusion- Few studies have investigated the long-term impact of prosthesis-patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR).
Abstract
Few studies have investigated the long-term impact of prosthesis-patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR). The study aimed to evaluate the long-term outcomes of patients with PPM following TAVR. A retrospective analysis was conducted in 1,221 consecutive patients who underwent TAVR at our institution between October 2013 and December 2022. The primary outcomes were all-cause and cardiovascular mortality within 10 years after TAVR. Of the 1,221 patients, moderate and severe PPM were observed in 220 (18.0%) and 58 (4.8%) patients, respectively. The predictors of PPM included a larger body surface area, a history of atrial fibrillation, dialysis (hemodialysis or peritoneal dialysis), lower left ventricular ejection fraction, smaller annular area, and the use of a balloon-expandable valve. During a median follow-up of 1,098 days (interquartile range: 661-1,833 days), no significant association was observed between PPM and either all-cause mortality or cardiovascular mortality (all-cause mortality: log-rank P = 0.385; and cardiovascular mortality: log-rank P = 0.467, respectively). In patients with a Society of Thoracic Surgery score of < 4%, multivariable Cox regression analysis showed that severe PPM was associated with cardiovascular mortality (hazard ratio: 3.106, 95% confidence interval: 1.151-8.377; P = 0.025). This subgroup finding should be interpreted cautiously and warrants further investigation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Prosthesis-Patient Mismatch and Patient-Centered Outcomes After TAVR.JACC. Cardiovascular interventions · 2026
- Mid-term impact of prosthesis-patient mismatch after transcatheter aortic valve implantation using a self-expanding or balloon-expandable transcatheter heart valveEuropean Heart Journal · 2026
- Incidence, Predictors, and Outcomes of Patient-Prosthesis Mismatch After Surgical Aortic Valve Replacement.Heart, lung & circulation · 2026
- Prosthesis–Patient Mismatch Following Aortic Valve Replacement—A Comprehensive ReviewJournal of Clinical Medicine · 2025
- Valve size matters: association of prosthesis size with mortality in patients without prosthesis-patient mismatch after surgical aortic valve replacement in a nationwide cohortEuropean Heart Journal · 2026
- Predictors of long-term structural valve deterioration and failure after transcatheter aortic valve implantationEuroIntervention · 2026