Preoperative AI-ECG analysis predicts paravalvular leak after transcatheter aortic valve replacement
N Razvi, K Lambeth, A Postalian, R Kalil, S Coulter, G V Silva, M Razavi, M W Segar
Key points
From the paper's conclusion- Background Paravalvular leak (PVL) following transcatheter aortic valve replacement (TAVR) remains associated with adverse outcomes and increased mortality.
Abstract
Background Paravalvular leak (PVL) following transcatheter aortic valve replacement (TAVR) remains associated with adverse outcomes and increased mortality. Current risk stratification relies primarily on anatomic features from cardiac CT, which incompletely capture the complex structural and functional remodelling influencing valve seating. The AccurKardia Aortic Valve Stenosis (AK-AVS) score is an artificial intelligence-enabled electrocardiographic (AI-ECG) biomarker validated to detect moderate-to-severe aortic stenosis by integrating electrical consequences of structural changes including left ventricular hypertrophy, fibrosis, and conduction abnormalities. Purpose To determine whether preoperative AK-AVS scores independently predict PVL. Methods We analysed 1,456 patients who underwent TAVR at our institution (2013-2024) after excluding patients with permanent pacemakers or missing preoperative AK-AVS scores. The AK-AVS score was derived from standard 12-lead ECGs obtained within 30 days prior to TAVR. PVL was graded according to Valve Academic Research Consortium-3 criteria as none, mild, or moderate-to-severe. Multivariable logistic regression models were adjusted for AK-AVS score (scaled per 0.10 increase) and established predictors: mean gradient, aortic valve area, aortic annulus diameter, valve size, aortic valve calcium score, device type (balloon-expanding [BEV] vs. self-expanding [SEV]), and STS risk score. Receiver operating characteristic curves were generated and area under the curve (AUC) values were compared using DeLong's test. Results Of 1,456 patients, 232 (15.9%) developed PVL. Patients with PVL had higher preoperative AK-AVS scores (0.71 vs. 0.67, p=0.011), lower ejection fraction (51.6% vs. 54.5%, p<0.001), larger valve size (27.3 vs. 26.2mm, p<0.001), higher calcium burden (2,743 vs. 2,413 Agatston units, p=0.001), and higher STS scores (6.4% vs. 5.4%, p=0.003) (Figure 1). Each 0.10 increase in AK-AVS score independently predicted PVL (OR 1.10, 95% CI 1.03-1.22, p=0.028) after adjusting for other predictors. Addition of AK-AVS to the base clinical model improved discrimination, increasing AUC from 0.643 (95% CI 0.609-0.677) to 0.686 (95% CI 0.653-0.719), p=0.007 (Figure 2A). In ordinal regression examining PVL severity, each 0.10 increase in AK-AVS score was associated with 12% higher odds of more severe PVL (OR 1.12, 95% CI 1.03-1.22, p=0.01). A clear dose-response relationship was evident: mean AK-AVS scores were 0.67 (SD 0.20) for no PVL, 0.71 (SD 0.19) for mild PVL, and 0.78 (SD 0.18) for moderate-to-severe PVL (Figure 2B). Conclusion Preoperative AK-AVS scores independently predict PVL development and severity following TAVR, providing incremental value beyond traditional clinical, echocardiographic, and procedural risk factors. This universally available AI-ECG biomarker may aid preprocedural risk stratification and guide valve selection or procedural planning to minimize PVL risk.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development of a risk stratification model for permanent pacemaker implantation after Transcatheter Aortic Valve Replacement (TAVR)European Heart Journal · 2026
- Ai-enabled baseline ECG for staging secondary cardiac damage in severe aortic stenosis undergoing TAVIi: a retrospective studyEuropean Heart Journal · 2026
- Prognostic Value of Artificial Intelligence–Enabled Electrocardiography–Derived Diastolic Dysfunction Grading and Trajectory in Patients Undergoing Transcatheter Aortic Valve ReplacementJournal of the American Heart Association · 2026
- Multimodal CT-echocardiographic score for preprocedural prediction of permanent pacemaker implantation after transcatheter aortic valve replacementEuropean Heart Journal · 2026
- Aortic valve calcification and one-year paravalvular leak after transcatheter aortic valve replacement: limited role of asymmetry.The Journal of invasive cardiology · 2026
- Association between annular eccentricity and initial post-deployment paravalvular leak before corrective maneuvers in bicuspid aortic valve patients undergoing self-expanding transcatheter aortic valve replacement: a single-center retrospective study.Frontiers in cardiovascular medicine · 2026