Biomechanical evaluation of various cage implantation angles and screw constructs in L4-5 PLIF surgery: a finite element study.
Hali Habulihan, Aoran Maheshati, Jitao Yang, Yalikun Yusufu, Yi Yang, Hailong Guo, Paerhati Rexiti
Department of Minimally Invasive Spine Surgery and Precision Orthopedics, The First Affiliated Hospital of Xinjiang Medical University, 137 Liyushan South Road, Urumqi, 830011, China. · Department of Spine Surgery, People's Hospital of Xinjiang Uygur Autonomous Region, Urumqi, 830001, China.
Key points
From the paper's conclusion- CBT screws achieved the highest ROM at 45° but with elevated disc stress. MCBT screws showed lower disc stress and moderate ROM. No single construct or angle was uniformly favorable across all parameters in this finite element model.
Abstract
BACKGROUND: This study investigates the biomechanical impact of different pedicle screw constructs and cage implantation angles on the L4-L5 segment. The aim is to optimize spinal stability and mobility in Posterior Lumbar Interbody Fusion (PLIF) surgery. METHODS: Three cadaveric specimens with osteoporotic bone density were used to construct finite element models of the L1-S1 segment. The L4-L5 segment underwent posterior lumbar interbody fusion (PLIF) surgery with three screw constructs: traditional pedicle screws (TT-TT), cortical bone trajectory screws (CBT-CBT), and modified cortical bone trajectory screws (MCBT-MCBT), with cage implantation angles of 30°, 45°, 60°, and 90°. Biomechanical analysis was performed under various loading conditions using ANSYS Workbench 19.1. Parameters such as range of motion, intervertebral disc stress, and pedicle screw stress were calculated to assess the effects of different fixation techniques and angles. RESULTS: The finite element analysis validated the impact of different screw types and cage angles on L4-L5 biomechanics. At 45°, all screw types showed the highest range of motion (ROM) in most directions. CBT screws resulted in higher intervertebral disc stress, particularly at 45° and 60°. Pedicle screw stress remained stable across angles, with MCBT exhibiting higher stress in lateral bending. Rod stress increased markedly at 60° and 90° for CBT, while MCBT showed higher stress during rotation. The results highlight the biomechanical effects of screw constructs and implantation angles on spinal stability. CONCLUSION: CBT screws achieved the highest ROM at 45° but with elevated disc stress. MCBT screws showed lower disc stress and moderate ROM. No single construct or angle was uniformly favorable across all parameters in this finite element model.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biomechanical effects of different bone conditions on oblique lumbar interbody fusion augmented with various fixation options: a finite element analysis.Frontiers in bioengineering and biotechnology · 2026
- Cage-Orientation-Dependent Biomechanics of Endoscopic-Compatible Bidirectional Cortical Bone Trajectory-Modified Translaminar Facet Screw Fixation versus Bilateral Percutaneous Pedicle Screw Fixation in Osteoporotic TLIF: A Finite Element Study.Medical engineering & physics · 2026
- Biomechanical advantages of double-trajectory screws technique combined with multiple-rod constructs in lumbar pedicle subtraction osteotomy: a finite element analysis study.Frontiers in bioengineering and biotechnology · 2026
- Biomechanical comparison of stand-alone interbody bone grafting versus cage implantation in ULIF: a finite element analysisScientific Reports · 2026
- Biomechanical study of posterior lumbar fixation combined with partial laminectomy using finite element analysisBIO Web of Conferences · 2026
- Effects of L4-L5 fusion on the adjacent levels in the lumbar spine.Biomedical physics & engineering express · 2026