Cage-Orientation-Dependent Biomechanics of Endoscopic-Compatible Bidirectional Cortical Bone Trajectory-Modified Translaminar Facet Screw Fixation versus Bilateral Percutaneous Pedicle Screw Fixation in Osteoporotic TLIF: A Finite Element Study.
Yixi Wang, Jitao Yang, Yang Xiao, Rui Zhang, Hali Habulihan, Paerhati Rexiti
The First Affiliated Hospital of Xinjiang Medical University, 137 Liyushan South Road, Xinshi District, Urumqi 830054, Xinjiang, China, Urumqi, Xinjiang, 830054, China. · Department of Minimally Invasive Spine and Precision Orthopedics, The First Affiliated Hospital of Xinjiang Medical University, 137 Liyushan South Road, Xinshi District, Urumqi 830054, Xinjiang, China, Urumqi, 830054, China.
Key points
From the paper's conclusion- IAS favors BCBT-MTFS for cranial disc, cage, and rod stresses, and BPPS for screw stress and fused-segment control.
Conclusions: In osteoporotic TLIF, cage orientation shapes construct biomechanics through fixation-specific load sharing rather than stiffness alone, supporting joint selection of fixation and cage position based on anticipated failure modes, local mechanical reserve, and endosco
Abstract
Bilateral percutaneous pedicle screw (BPPS) fixation is constrained by cancellous bone dependence in osteoporosis and limited compatibility with endoscopic workflows. The newly proposed bidirectional cortical bone trajectory-modified translaminar facet screw (BCBT-MTFS) fixation enables endoscopic bilateral cortical fixation. Its uncertain biomechanics motivated a comparison with BPPS across cage insertion angles. Methods: Geometry-specific L1-S1 finite element models from three osteoporotic spines simulated L4-5 TLIF with BPPS or BCBT-MTFS at cage insertion angles of 30°, 45°, 60°, and 90° under a 400 N follower preload and 7.5 N·m pure moments. Multilevel range of motion (ROM), adjacent-disc and implant stresses were designated as primary outcomes, alongside additional measures of implant-bone interface loading. The Angle Sensitivity Index (ASI), Composite Mechanical Response (CMR), Mechanical Coupling Index (MCI), and Integrated Advantage Score (IAS) were calculated from the primary outcomes to integrate multidimensional biomechanical responses and evaluate overall construct performance. Results: Relative to BPPS, BCBT-MTFS reduces multilevel ROM (12.7-46.2%) and rod stress (24.5-60.3%) in flexion, selectively lowers cranial disc and rod loading under axial rotation and lateral bending, and reduces estimated screw-bone shear force across all tested conditions. Trade-offs include higher cranial disc stress in flexion and, in extension, weaker restraint (24.5-49.0% greater fused-segment ROM), higher implant loading and cage-endplate pressure. ASI identifies cage and posterior instrumentation stresses as the most cage-insertion-angle-sensitive metrics in BCBT-MTFS, versus disc stresses in BPPS. With increasing cage obliquity, BCBT-MTFS shows smoother CMR and declining MCI, whereas BPPS shows CMR amplification near 60° and stronger high-obliquity coupling. IAS favors BCBT-MTFS for cranial disc, cage, and rod stresses, and BPPS for screw stress and fused-segment control. Conclusions: In osteoporotic TLIF, cage orientation shapes construct biomechanics through fixation-specific load sharing rather than stiffness alone, supporting joint selection of fixation and cage position based on anticipated failure modes, local mechanical reserve, and endoscopic requirements.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biomechanical advantages of double-trajectory screws technique combined with multiple-rod constructs in lumbar pedicle subtraction osteotomy: a finite element analysis study.Frontiers in bioengineering and biotechnology · 2026
- Biomechanical evaluation of various cage implantation angles and screw constructs in L4-5 PLIF surgery: a finite element study.BMC musculoskeletal disorders · 2026
- Biomechanical evaluation of a fully cortical-threaded screw for modified cortical bone trajectory fixation: Combined experimental and finite element studyProceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · 2026
- Biomechanical effects of different bone conditions on oblique lumbar interbody fusion augmented with various fixation options: a finite element analysis.Frontiers in bioengineering and biotechnology · 2026
- Direction-dependent biomechanical effects of transverse process hooks versus pedicle screws at the uppermost instrumented vertebra in adult spinal deformity: a finite element analysis.Frontiers in bioengineering and biotechnology · 2026
- Biomechanical comparison of laminoplasty and in-site regrafting versus laminectomy with pedicle screw fixation for localized thoracic pathological ossification of the ligamentum flavum: a finite element analysis.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026