Biomechanical study of posterior lumbar fixation combined with partial laminectomy using finite element analysis
Natpataisak Thongmaha, Supakit Rooppakhun, Terdpong Tanaviriyachai
Key points
From the paper's conclusion- These findings indicate that PS fixation provides superior segmental stability, whereas Uni-PS+TS fixation may serve as a less invasive alternative in selected clinical situations, such as when bilateral pedicle screw placement is contraindicated.
Abstract
This study investigates the biomechanical performance of posterior lumbar fixation following partial laminectomy using the finite element (FE) method. Two fixation techniques at the L4–L5 level were evaluated: (1) bilateral pedicle screw fixation (PS) and (2) a hybrid construct combining unilateral pedicle screw and contralateral transforaminal screw fixation (Uni-PS+TS). We developed a three-dimensional FE model of the lumbar spine to simulate postoperative changes and physiological loading. Six motion directions were analyzed under a 500 N preload combined with a 10 Nm moment. The Uni-PS+TS construct produced higher maximum von Mises stresses across all loading conditions, particularly in flexion and lateral bending, with stress concentration along the transforaminal screw shaft. The PS construct reduced range of motion by 15–33% compared with Uni-PS+TS. These findings indicate that PS fixation provides superior segmental stability, whereas Uni-PS+TS fixation may serve as a less invasive alternative in selected clinical situations, such as when bilateral pedicle screw placement is contraindicated.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Finite Element Comparison of Unilateral and Bilateral Polymethylmethacrylate Vertebral Fixation in the Canine Thoracolumbar Spine.Veterinary and comparative orthopaedics and traumatology : V.C.O.T · 2026
- Assessing the Clinical Utility of Finite Element Analysis Using Post-operative CT-Derived Models: A Material Comparison of Multi-level Spinal Fusion ConstructsbioRxiv · 2026
- Biomechanical advantages of double-trajectory screws technique combined with multiple-rod constructs in lumbar pedicle subtraction osteotomy: a finite element analysis study.Frontiers in bioengineering and biotechnology · 2026
- Biomechanical comparative analysis of minimally invasive decompression and minimally invasive fusion with internal fixation in the treatment of lumbar spinal stenosis with degenerative spondylolisthesis: a finite element study.BMC musculoskeletal disorders · 2026
- Biomechanical comparison of laminoplasty and in-site regrafting versus laminectomy with pedicle screw fixation for localized thoracic pathological ossification of the ligamentum flavum: a finite element analysis.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
- Biomechanical Comparison of Unilateral Biportal Endoscopy and Percutaneous Endoscopic Lumbar Discectomy Using a Finite Element ModelJOR SPINE · 2026