Biomechanical comparison of stand-alone interbody bone grafting versus cage implantation in ULIF: a finite element analysis
Chunyang Xu, Yukan Wu, Jiaguang Tang
Beijing Tongren Hospital
Key points
From the paper's conclusion- A subject-specific L4-L5 finite element model with residual Grade I spondylolisthesis was used to compare bilateral pedicle-screw fixation with stand-alone interbody impaction bone grafting versus porous titanium cage implantation.
Abstract
The biomechanical differences between stand-alone interbody bone grafting and cage implantation in unilateral biportal endoscopic lumbar interbody fusion (ULIF) remain unclear. This study compared the two strategies in a patient-specific finite element model and assessed model credibility using geometric reconstruction, published range-of-motion (ROM) data, and mesh convergence analysis. A subject-specific L4-L5 finite element model with residual Grade I spondylolisthesis was used to compare bilateral pedicle-screw fixation with stand-alone interbody impaction bone grafting versus porous titanium cage implantation. A 500-N axial preload and a 7.5-N m pure moment were applied independently in six directions. Segmental ROM, model-reported stiffness, and von Mises stresses in the interbody constructs, screw-rod system, and endplates were evaluated. ROM was calculated from the relative rotation of L4 with respect to L5. In addition to comparison with published cadaveric ROM, five characteristic mesh sizes (4.0, 3.5, 3.0, 2.5, and 2.0 mm) were assessed under identical model settings. Cage implantation reduced ROM by 30.4%-37.3% across the six loading directions and produced higher model-reported stiffness than stand-alone bone grafting. The cage model also generated higher localized stresses in the interbody construct and screw-rod system; during right lateral bending, screw and rod stresses increased by 556.6% and 361.2%, respectively. Endplate effects were direction- and level-dependent, including a 326.7% increase at the L4 inferior endplate during right lateral bending. In the mesh study, the monitored von Mises stresses for 4.0-, 3.5-, 3.0-, 2.5-, and 2.0-mm meshes were 6.820, 11.499, 9.849, 9.865, and 9.840 MPa, respectively; the maximum pairwise difference among meshes of 3.0 mm or finer was 0.25%. Within the prescribed loading, material, contact, and mesh assumptions of this single patient-specific model, cage implantation provided greater immediate segmental restraint but generated a less favorable localized stress environment in selected implant and endplate regions. Stand-alone bone grafting produced greater motion but a more diffuse load-transfer pattern. The mesh convergence results support numerical stability of the reported stress solution but do not constitute independent biological validation. These computational findings are hypothesis-generating and should not be interpreted as proof of clinical superiority, long-term safety, or a direct basis for patient selection.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biomechanical effects of different bone conditions on oblique lumbar interbody fusion augmented with various fixation options: a finite element analysis.Frontiers in bioengineering and biotechnology · 2026
- Biomechanical comparative analysis of minimally invasive decompression and minimally invasive fusion with internal fixation in the treatment of lumbar spinal stenosis with degenerative spondylolisthesis: a finite element study.BMC musculoskeletal disorders · 2026
- Modular Cage-Type Prosthetic Construction for Lumbar Intervertebral Reconstruction: A Computer-Aided Design-Based Geometric Design and Finite Element Analysis Study.Cureus · 2026
- Biomechanical evaluation of various cage implantation angles and screw constructs in L4-5 PLIF surgery: a finite element study.BMC musculoskeletal disorders · 2026
- Radiological decompression and clinical outcomes following endoscopic unilateral biportal lumbar interbody fusion vs. conventional posterior lumbar interbody fusion.Frontiers in radiology · 2026
- Biomechanical study of posterior lumbar fixation combined with partial laminectomy using finite element analysisBIO Web of Conferences · 2026