Effects of L4-L5 fusion on the adjacent levels in the lumbar spine.
M T Alonso Rasgado, F M Martinez-Lozada, Gurpreet Singh, Colin G Bailey, Rajat Verma, Saeed Mohammad
School of Engineering and Materials Science, Queen Mary University of London, Mile End Road, London, E1 4NS, United Kingdom of Great Britain and Northern Ireland. · School of Mechanical, Aerospace and Civil Engineering, The University of Manchester, Oxford Road, Manchester, England, M13 9PL, United Kingdom of Great Britain and Northern Ireland.
Key points
From the paper's conclusion- Flexion generated the highest stresses, approximately 90% greater than extension and 35% greater than compression, highlighting the sensitivity of postoperative load sharing to loading direction.

These findings show that L4–L5 fusion alters stress distribution within the fused segment and the superior adjacent level, providing comparative biomechanical insight into how construct design an
Abstract
Spondylolisthesis and degenerative disc disease can, in some cases, be treated using lumbar fusion techniques; however, the effects of these procedures on the surgical site, adjacent vertebral bodies, and intervertebral discs are not fully understood. In this work, a three-dimensional finite element model of the L1-L5 lumbar spine was developed using Computed Tomography data from a healthy individual, to evaluate stress redistribution following L4-L5 fusion. Four models were evaluated: a healthy spine without instrumentation; a spine with pedicle screw fixation at L4-L5; a spine with pedicle screw fixation and interbody cages at L4-L5; and a spine with interbody fusion at L4-L5. The analysis considered three loading conditions: axial compression, flexion, and extension. Percentage changes in vertebrae cortical-bone and intervertebral lumbar disc stress were calculated relative to the healthy-spine value under the same loading condition. Average von Mises stresses in the L1-L3 cortical bone and the L1-L2 and L2-L3 intervertebral discs remained similar to the healthy spine. Fusion reduced stress in the L4 vertebra relative to the screw-only construct, whereas L5 cortical bone stress increased across all instrumented configurations. Screw only fixation produced the largest increases, while the fused screw and cage construct produced the smallest, demonstrating that construct design and fusion state influence load redistribution at the fused level. The superior adjacent L3-L4 disc experienced a consistent 34-42% increase in stress across all instrumented models, indicating elevated adjacent segment loading even when cage-based constructs reduced stresses at L5. Flexion generated the highest stresses, approximately 90% greater than extension and 35% greater than compression, highlighting the sensitivity of postoperative load sharing to loading direction. These findings show that L4-L5 fusion alters stress distribution within the fused segment and the superior adjacent level, providing comparative biomechanical insight into how construct design and loading conditions influence postoperative load transfer. 
.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biomechanical comparative analysis of minimally invasive decompression and minimally invasive fusion with internal fixation in the treatment of lumbar spinal stenosis with degenerative spondylolisthesis: a finite element study.BMC musculoskeletal disorders · 2026
- Assessing the Clinical Utility of Finite Element Analysis Using Post-operative CT-Derived Models: A Material Comparison of Multi-level Spinal Fusion ConstructsbioRxiv · 2026
- Does Additional Distal S2 Fixation Improve Lumbosacral Stability Compared with Standard L4-S1 Fixation in High-Grade Spondylolisthesis? A Prospective Randomised Comparative Study.Spine · 2026
- Biomechanical evaluation of various cage implantation angles and screw constructs in L4-5 PLIF surgery: a finite element study.BMC musculoskeletal disorders · 2026
- Biomechanical study of posterior lumbar fixation combined with partial laminectomy using finite element analysisBIO Web of Conferences · 2026
- Evaluation of Clinical and Radiological Outcomes of Rigid, Dynamic, and Hybrid Stabilization Systems in Degenerative Lumbar Spine Surgery.Journal of clinical medicine · 2026