Phlebotomy technique and its impact on haemolysis in the emergency department.
Jonathan Fenn, Ahmed Elgharably, Shivani Mahapatra, Thushi Ashmore, Lauren Starbrook, Rousseau Gama, Tejas Kalaria
Clinical Biochemistry, Black Country Pathology Services, The Royal Wolverhampton NHS Trust, Wolverhampton, UK. · Emergency Medicine, The Royal Wolverhampton NHS Trust, Wolverhampton, UK.
Key points
From the paper's conclusion- This study evaluated the association between phlebotomy techniques and haemolysis rates in the emergency department.MethodsBlood samples collected in the emergency department with documented phlebotomy technique between November 2023 and September 2024 were audited.
Abstract
BackgroundHaemolysis is a pre-analytical problem that compromises laboratory test accuracy and delays care by necessitating repeat testing. Haemolysis rates in emergency department samples are higher than those in inpatient or outpatient settings. This study evaluated the association between phlebotomy techniques and haemolysis rates in the emergency department.MethodsBlood samples collected in the emergency department with documented phlebotomy technique between November 2023 and September 2024 were audited. Five phlebotomy methods were compared: [1] needle/butterfly to vacutainer (closed system), [2] syringe-needle draw, [3] syringe draw from an intravenous cannula, [4] vacutainer collection from cannula using an adapter, and [5] use of a discard tube for either needle or cannula draws. Haemolysis was defined by an Abbott Alinity H-index ≥1.25 (≈1.25 g/L free haemoglobin), above which potassium results are suppressed by the laboratory.ResultsAmong 586 samples, 42 (7.2%) were haemolysed. Haemolysis rates were 16.7% (2/12) for syringe draw from intravenous cannula, 14.8% (31/209) for vacutainer collection from intravenous cannula using an adapter, 6.3% (1/16) for syringe-needle draw, 2.4% (2/83) for methods using a discard-tube in either needle or cannula collection, and 2.3% (6/266) for needle/butterfly to vacutainer closed phlebotomy method. Haemolysis differed significantly by method (p < 0.0001): draws from cannula using adapter had higher rates than closed phlebotomy (p < 0.0001) and discard-tube draws (p = 0.0017).ConclusionClosed phlebotomy methods, particularly needle or butterfly collection into vacutainer tubes, were associated with the lowest haemolysis rates. Discard-tube samples also had low haemolysis rates, although their effect remains uncertain.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of Early Tourniquet Release on Hemolysis in Emergency Department Phlebotomy: The TOURNI-ED Randomized Trial.Medicina (Kaunas, Lithuania) · 2026
- A-277 Improving Sample Integrity: Preclinical Evidence Demonstrating Reduced Hemolysis with Novel Blood Collection DeviceClinical Chemistry · 2026
- 39 Reduction of Serum Hemolysis in the Emergency Department Using a Needleless PIVO™(BD) Blood Collection DeviceAmerican Journal of Clinical Pathology · 2026
- Real-world implementation of EUSEM/EuSEN/EFLM blood sampling recommendations in an adult emergency department: impact on hemolysis and potassium result availability.Clinical chemistry and laboratory medicine · 2026
- An Autonomous Robotic Phlebotomy Device: Extended Analytical Validation and Real-World Hemolysis Assessment.Diagnostics (Basel, Switzerland) · 2026
- Preanalytical interventions to reduce hemolysis and improve specimen quality: a systematic review and meta-analysis.Laboratory medicine · 2026