Effect of Early Tourniquet Release on Hemolysis in Emergency Department Phlebotomy: The TOURNI-ED Randomized Trial.
Emir Ünal, Furkan Ünal, Onatcan Ozogul, Mümin Murat Yazıcı, Eren Onur Karavin, Erhan Altunbas, Sinan Karacabey, Ali Çelik
Department of Emergency Medicine, Marmara University School of Medicine, Istanbul 34899, Türkiye. · Nursing Services, Marmara University Pendik Training and Research Hospital, Istanbul 34899, Türkiye.
Key points
From the paper's conclusion- These findings cannot be generalized to resuscitated patients (ESI 1–2), intravenous catheter blood draws, winged collection devices, or uncalibrated elastic tourniquets.
Abstract
Background and Objectives: Hemolysis is the most common preanalytical error in emergency department samples and can compromise diagnostic reliability. Evidence on tourniquet-release timing under standardized pressure is limited. We assessed whether initiating cuff deflation when blood enters the first tube and completing it as that tube fills reduces hemolysis. Materials and Methods: In a single-center, parallel-group, 1:1 randomized trial (ClinicalTrials.gov NCT07617103), 792 adults triaged as Emergency Severity Index (ESI) 3 to 5 underwent venipuncture with stasis applied at 60 mm Hg by sphygmomanometer. Cuff deflation was initiated when blood entered the first tube and completed as that tube filled (n = 396) or after the last tube filled (n = 396). The primary outcome was the proportion of serum separator gel tubes with a hemolysis index of 1+ or greater, assessed by personnel blinded to allocation. The primary complete-case analysis included 790 participants analyzed as randomized. Results: Hemolysis occurred in 68 of 395 patients (17.2%) with early release and 103 of 395 (26.1%) with late release (absolute risk reduction 8.9 percentage points; 95% confidence interval (CI), 3.1-14.5; p = 0.003; number needed to treat (NNT) 11.3). The adjusted odds ratio in the prespecified model was 0.58 (95% CI, 0.41-0.82), and the ordinal distribution also favored early release (p = 0.002). No early-release patient exceeded 60 s of stasis, versus 29.0% with late release. Complication estimates were imprecise (8.1% vs. 5.6%; risk difference +2.5 points; 95% CI, -1.0 to 6.1). Conclusions: In adult emergency department patients presenting with non-critical acuity (ESI 3-5) undergoing direct 21-gauge venipuncture under standardized 60 mm Hg cuff pressure, early cuff release significantly reduced specimen hemolysis (NNT 11.3 for preventing one laboratory-defined hemolyzed sample). These findings cannot be generalized to resuscitated patients (ESI 1-2), intravenous catheter blood draws, winged collection devices, or uncalibrated elastic tourniquets.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Real-world implementation of EUSEM/EuSEN/EFLM blood sampling recommendations in an adult emergency department: impact on hemolysis and potassium result availability.Clinical chemistry and laboratory medicine · 2026
- Phlebotomy technique and its impact on haemolysis in the emergency department.Annals of clinical biochemistry · 2026
- Preanalytical interventions to reduce hemolysis and improve specimen quality: a systematic review and meta-analysis.Laboratory medicine · 2026
- A-277 Improving Sample Integrity: Preclinical Evidence Demonstrating Reduced Hemolysis with Novel Blood Collection DeviceClinical Chemistry · 2026
- 39 Reduction of Serum Hemolysis in the Emergency Department Using a Needleless PIVO™(BD) Blood Collection DeviceAmerican Journal of Clinical Pathology · 2026
- 182 Leveraging an Automated Delta-Check Rule to Flag Critical Preanalytical Errors in Coagulation Testing: A 14-Month Lab Practice InterventionAmerican Journal of Clinical Pathology · 2026