Preanalytical interventions to reduce hemolysis and improve specimen quality: a systematic review and meta-analysis.
Young-Hee Lee, Ho-Keun Choi, Kyung A Jung, Hyun Ho Sung
Department of Nursing, Dongnam Health University, Suwon, Republic of Korea. · Department of Biomedical Laboratory Science, College of Health Sciences, Sangji University, Wonju, Republic of Korea.
Key points
From the paper's conclusion- Discussion Preanalytical quality interventions may reduce hemolysis and improve specimen quality, but evidence remains limited by heterogeneity, nonrandomized designs, and inconsistent outcome reporting.
Abstract
INTRODUCTION: Hemolysis and other preanalytical errors compromise laboratory test accuracy, delay reporting, and may require repeat specimen collection. METHODS: We conducted a PROSPERO-registered systematic review and meta-analysis following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses 2020 statement. PubMed/MEDLINE and KoreaMed were searched from inception to May 17, 2026, with supplementary manual and institutional source searching. Eligible studies evaluated preanalytical interventions related to blood specimen collection or handling and reported hemolysis, specimen rejection, recollection, misidentification, or broader preanalytical error outcomes. Risk ratios for hemolysis were pooled using a random-effects model; secondary outcomes were summarized narratively. RESULTS: Seventeen studies were included in the qualitative synthesis, and 7 provided event and denominator data for hemolysis meta-analysis. Preanalytical interventions reduced hemolysis compared with conventional practice (risk ratio, 0.48 [95% CI, 0.28-0.81]; P = .0066), representing an approximately 52% relative risk reduction. Heterogeneity was substantial (I2 = 92.4%). Secondary studies generally reported reductions in sample rejection, nonconforming specimens, or broader preanalytical errors. Certainty of evidence was low for hemolysis and very low for secondary outcomes. DISCUSSION: Preanalytical quality interventions may reduce hemolysis and improve specimen quality, but evidence remains limited by heterogeneity, nonrandomized designs, and inconsistent outcome reporting.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Why do hemolysis interference studies produce different results? A proposal for standardized experimental design and reportingClinical Chemistry and Laboratory Medicine (CCLM) · 2026
- Effect of Early Tourniquet Release on Hemolysis in Emergency Department Phlebotomy: The TOURNI-ED Randomized Trial.Medicina (Kaunas, Lithuania) · 2026
- A-277 Improving Sample Integrity: Preclinical Evidence Demonstrating Reduced Hemolysis with Novel Blood Collection DeviceClinical Chemistry · 2026
- Spectrum of Preanalytical Laboratory Errors in Clinical Biochemistry Laboratory in a Tertiary Care Center in Nepal.Kathmandu University medical journal (KUMJ) · 2025
- Simulation Study on Preanalytical Variables in Coagulation Testing: Interference Effects and Threshold Determination of Hemolysis, Lipemia, Icterus and Insufficient Sample Volume.Clinical and applied thrombosis/hemostasis : official journal of the International Academy of Clinical and Applied Thrombosis/Hemostasis · 2026
- Real-world implementation of EUSEM/EuSEN/EFLM blood sampling recommendations in an adult emergency department: impact on hemolysis and potassium result availability.Clinical chemistry and laboratory medicine · 2026