A-277 Improving Sample Integrity: Preclinical Evidence Demonstrating Reduced Hemolysis with Novel Blood Collection Device
Saardhak Bhrugubanda, Natasha Mody, Brinley Canon, Amanda Maxwell, Lukas Ramcharran
Key points
From the paper's conclusion- We developed a novel blood collection device designed to modulate aspiration pressure in real time, maintaining physiologic flow conditions and reducing red blood cell shear stress during intravenous sampling.
Abstract
Background Hemolysis during blood collection remains one of the most common pre-analytical errors in clinical diagnostics, leading to specimen rejection, repeat phlebotomy, delayed clinical decisions, and increased healthcare costs. A primary contributor to in vitro hemolysis is excessive negative pressure and turbulent shear forces generated during manual aspiration with conventional syringes. We developed a novel blood collection device designed to modulate aspiration pressure in real time, maintaining physiologic flow conditions and reducing red blood cell shear stress during intravenous sampling. This preclinical large-animal study evaluates device feasibility, safety, and hemolysis reduction compared to a standard syringe. Methods Thirty healthy Yorkshire pigs (>20 kg) were sedated or anesthetized per veterinary protocol. Paired venous blood draws were performed from lateral saphenous veins using both the investigational pressure-modulating device and a standard syringe in randomized order, with 5 to 7 mL collected per device per draw following a 2 mL waste discard. Catheter gauge, venipuncture site, and collection workflow were standardized. Samples were coded and processed within one hour. Plasma-free hemoglobin (g/L) was quantified via spectrophotometry. Laboratory personnel were blinded to device allocation. Hemolysis severity was categorized using CDC reference thresholds. Mean plasma-free hemoglobin and the proportion of samples exceeding clinically relevant hemolysis thresholds (=0.2 g/L and =0.5 g/L) were compared between devices. Results The protocol was successfully executed with consistent handling and blinded analysis. Preliminary data from 11 paired samples demonstrate lower plasma-free hemoglobin concentrations in 100% of samples collected with the pressure-modulating device compared to standard syringe aspiration. No investigational device samples exceeded the gross hemolysis threshold (=2.5 g/L). Final statistical analysis across the full cohort (N=30) will be presented at the conference. Conclusion In a controlled porcine model, a novel pressure-modulating blood collection device demonstrated feasibility, and a consistent reduction in hemolysis relative to standard syringe collection. By reducing excessive negative pressure during aspiration, the device may improve specimen integrity and decrease pre-analytical laboratory errors. These findings support continued translational development toward clinical evaluation in high-acuity care settings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- 39 Reduction of Serum Hemolysis in the Emergency Department Using a Needleless PIVO™(BD) Blood Collection DeviceAmerican Journal of Clinical Pathology · 2026
- An Autonomous Robotic Phlebotomy Device: Extended Analytical Validation and Real-World Hemolysis Assessment.Diagnostics (Basel, Switzerland) · 2026
- Preanalytical interventions to reduce hemolysis and improve specimen quality: a systematic review and meta-analysis.Laboratory medicine · 2026
- Effect of Early Tourniquet Release on Hemolysis in Emergency Department Phlebotomy: The TOURNI-ED Randomized Trial.Medicina (Kaunas, Lithuania) · 2026
- Phlebotomy technique and its impact on haemolysis in the emergency department.Annals of clinical biochemistry · 2026
- Methodology for computational assessment of hemolysis in under-occlusive roller pumps operated at clinically relevant conditions.Bioengineering & translational medicine · 2026