Evaluating Standard Shielding Versus Novel Enhanced Radiation Protection Devices in the Cardiac Catheterization Laboratory.
Raviteja R Guddeti, Christian W Schmidt, Robert F Riley, Jacob Kamen, Jarrod Frizzell, Korey Haddox, James Kong, Steven Rudick,
The Carl and Edyth Lindner Center for Research and Education at The Christ Hospital Cincinnati OH USA. · Overlake Medical Center Bellevue WA USA.
Key points
From the paper's conclusion- Compared with standard shielding, ERPDs significantly lowered scatter radiation exposure to all members of the cardiac catheterization laboratory.
Abstract
BACKGROUND: Enhanced radiation protection devices (ERPDs) have the potential to reduce occupational risks in the cardiac catheterization laboratory. We aimed to investigate scatter radiation exposure to various cardiac catheterization laboratory members using 2 ERPDs. METHODS: We prospectively allocated cases to 3 different shielding conditions: standard shielding (group 1), EggNest Protect ERPD (group 2), and EggNest Complete ERPD (group 3). Real-time dosimetry was used to measure radiation exposure at 3 positions: primary operator (position 1), assistant (position 2), and circulating nurse (position 3). Effective dose equivalent was estimated (annualized to 300 cases/y). RESULTS: A total of 135 patients were included in the study (mean age, 68±11 years; 73% men). For position 1, annualized effective dose equivalent -1 doses were 51.4 (19.1-101.3), 7.0 (2.3-21.5), and 2.4 (0.9-6.2) mRem for groups 1, 2, and 3, respectively (P<0.001) standard shielding versus Protect ERPD: 33.1 (95% CI, 11.1-62.9), standard shielding versus Complete ERPD: 41.4 (20.5-71.9). For position 2, annualized effective dose equivalent -1 doses were 2.8 (2.0-6.3), 1.1 (0.6-6.4), and 0.8 (0.3-2.7) mRem for groups 1, 2, and 3, respectively (P<0.001) standard shielding versus Protect ERPD: 33.1 (95% CI, 11.1-62.9), standard shielding versus Complete ERPD: 41.4 (20.5-71.9). For position 3, annualized effective dose equivalent -1 doses were 1.5 (0.6-4.0), 1.5 (0.3-2.4), and 0.8 (0.2-2.5) mRem for groups 1, 2, and 3, respectively (P=0.003) standard shielding versus Protect ERPD: 0.3 (-0.4 to 1.2), standard shielding versus Complete ERPD: 0.4 (-0.1 to 1.4). With the use of the EggNest Complete ERPD without a lead apron, annualized total effective doses are ≤1% of the recommended annual maximum for all positions. CONCLUSIONS: Compared with standard shielding, ERPDs significantly lowered scatter radiation exposure to all members of the cardiac catheterization laboratory.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Randomized Evaluation of a Textile-Based Enhanced Radiation Protection Device Versus Control Shielding in the Cardiac Catheterization Laboratory.Journal of the Society for Cardiovascular Angiography & Interventions · 2026
- Impact of Radiation-Attenuating Drape on Exposure in a Contemporary Cardiac Catheterization Laboratory: The ATTENUATE Trial.Journal of the Society for Cardiovascular Angiography & Interventions · 2026
- Clinical evaluation of radiation-shielding effects of a head-and-neck X-ray protective device during cardiovascular interventional procedures.Radiological physics and technology · 2026
- Real-time Radiation Exposure Monitoring in the Cardiac Catheterization Laboratory Using a Digital RRPD Dosimeter.Health physics · 2026
- Spatial distribution of X-ray attenuation in a full-face shield: a multipoint in vivo study in interventional cardiology.Radiation protection dosimetry · 2026
- SCAI/ASE/HRS/SIR/SVS Expert Consensus Statement on Enhanced Radiation Protection: Time for Mandatory and Urgent Action.Journal of the Society for Cardiovascular Angiography & Interventions · 2026