SCAI/ASE/HRS/SIR/SVS Expert Consensus Statement on Enhanced Radiation Protection: Time for Mandatory and Urgent Action.
David G Rizik, Nadia R Sutton, Alexandra J Lansky, Mirvat Alasnag, Gabriel Bartal, Mary Beth Brady, Megan Coylewright, James A Goldstein,
Department of Cardiology, Banner University Medical Center, Scottsdale, Arizona. · Department of Internal Medicine, Division of Cardiovascular Medicine, Vanderbilt University Medical Center, Nashville, Tennessee.
Key points
From the paper's conclusion- This expert consensus statement outlines the ethical and legal responsibilities of government, fluoroscopy laboratory manufacturers, and health care institutions to protect all health care professionals from avoidable workplace hazards and the urgent need to implement ERPDs.
Abstract
Health care professionals in fluoroscopic laboratories face significant occupational hazards, including cancer, cataracts, and reproductive concerns due to prolonged exposure to iodizing radiation, and orthopedic injuries stemming from long-term use of heavy aprons as protection from radiation. Despite substantial advancements in radiation protection technology, adoption of these advancements has been slow, hindered by the high upfront costs of implementation and the lag in revising institutional and regulatory radiation exposure thresholds to reflect the capabilities of contemporary enhanced radiation protection devices (ERPDs). This multisociety statement, endorsed by the Society for Cardiovascular Angiography & Interventions, American College of Cardiology, the American Society of Echocardiography, the Heart Rhythm Society, the Society of Interventional Radiology, and the Society for Vascular Surgery, calls for mandatory implementation of ERPDs to meet as low as reasonably achievable standards. This expert consensus statement outlines the ethical and legal responsibilities of government, fluoroscopy laboratory manufacturers, and health care institutions to protect all health care professionals from avoidable workplace hazards and the urgent need to implement ERPDs. The document does not promote or recommend any single ERPD system, and the choice of protection technology is left to department preference. It also addresses the importance of training, monitoring, and continuous research to optimize radiation safety practices. The document advocates for updated regulations and standardized practices across states to ensure comprehensive protection for all fluoroscopy laboratory personnel.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Occupational Protection in Interventional Radiology. A Joint Guideline of the Cardiovascular and Interventional Radiological Society of Europe and the Society of Interventional RadiologyCardioVascular and Interventional Radiology · 2026
- Evaluation of occupational radiation exposure and safety practices among orthopedic surgeons using C-arm fluoroscopy: a preliminary study at a hospital in Palestine.Radiation protection dosimetry · 2026
- Real-time occupational radiation dosimetry in anesthesiology personnel during fluoroscopy-guided interventions: a single-center descriptive and exploratory study.Frontiers in public health · 2026
- Patient and occupational dosimetry in fluoroscopy-guided interventions in Spain: Progress made, gaps remaining.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026
- Occupational radiation exposure and radiation protection practices in interventional radiology and cardiology: A multicenter study in FranceDiagnostic and Interventional Imaging · 2026
- Recommendations From the Blue Ribbon Panel on Fluoroscopy SafetyJournal of the American College of Radiology · 2026