Real-time Radiation Exposure Monitoring in the Cardiac Catheterization Laboratory Using a Digital RRPD Dosimeter.
Arshad Nazir, Aditya Kapoor, Ankit Sahu, Arpita Katheria, Harshit Khare, Roopali Khanna, Naveen Garg, Satyendra Tewari
Department of cardiology, Sanjay Gandhi Post Graduate Institute of Medical Sciences, Lucknow-226014, Uttar Pradesh, India.
Key points
From the paper's conclusion- These findings indicate that real-time personal dosimetry enables continuous exposure monitoring and may support radiation-protective behaviors during high-dose interventional procedures.
Abstract
Occupational exposure to ionizing radiation remains an important concern for healthcare professionals working in x-ray-guided interventional environments. Conventional passive dosimetry provides retrospective dose assessment and does not permit immediate modification of operator behavior. We evaluated the feasibility and practical utility of a real-time radiation personal dosimeter (RRPD) during three chronic total occlusion (CTO) percutaneous coronary intervention procedures performed in a cardiac catheterization laboratory. Wearable dosimeters were positioned on the lead aprons of the primary and secondary operators and provided continuous wireless measurements of the dose rate and cumulative radiation exposure. Procedural parameters, including fluoroscopy time, air kerma, dose-area product (DAP), cine acquisition count, and operator dose, were recorded and compared with commonly reported reference ranges for CTO interventions. Radiation exposure increases with procedural complexity. Antegrade CTO procedures demonstrated fluoroscopy time, air kerma, and DAP values below the typical reference ranges, whereas a complex retrograde CTO procedure was associated with higher values consistent with prolonged fluoroscopy. Real-time visualization of radiation peaks was associated with timely operator adjustments without too much clinical interference, including reduced angulation and limitations of cine imaging. The primary operator exposure exceeded the secondary operator exposure in all cases. These findings indicate that real-time personal dosimetry enables continuous exposure monitoring and may support radiation-protective behaviors during high-dose interventional procedures.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Real-time occupational radiation dosimetry in anesthesiology personnel during fluoroscopy-guided interventions: a single-center descriptive and exploratory study.Frontiers in public health · 2026
- Real-time dosimetry in interventional radiology—comparing the operators’ radiation dose and associated factors for five types of transarterial embolization proceduresFrontiers in Public Health · 2026
- Operator radiation exposure between left distal and right conventional radial access in patients undergoing PCIEuropean Heart Journal · 2026
- Ultra-Low-Dose Noise-Free Technology to Reduce Radiation Exposure During Coronary AngiographyCirculation Cardiovascular Interventions · 2026
- Evaluating Standard Shielding Versus Novel Enhanced Radiation Protection Devices in the Cardiac Catheterization Laboratory.Journal of the American Heart Association · 2026
- Occupational radiation exposure and radiation protection practices in interventional radiology and cardiology: A multicenter study in FranceDiagnostic and Interventional Imaging · 2026