Spatial distribution of X-ray attenuation in a full-face shield: a multipoint in vivo study in interventional cardiology.
Faustino Bonutti, Enrico Favaretto, Ana Gisel Garcia Alvarado, Veronica Rosso, Sarah Bassi, Serena D'Agostini, Eugenia Moretti
Medical Physics Department, University Hospital, Udine, Piazzale S. Maria della Misericordia n. 15, 33100 Udine, Italy. · Interventional Cardiology, Division of Cardiology, University Hospital, Udine, Piazzale S. Maria della Misericordia n. 15, 33100 Udine, Italy.
Key points
From the paper's conclusion- This study evaluates the protective efficacy of a 0.12 mmPb leaded acrylic full-face shield through a series of comprehensive in vivo dose measurements conducted on a primary cardiologist during real-time fluoroscopy procedures.
Abstract
Occupational radiation exposure remains a critical concern in interventional cardiology, particularly regarding brain and ocular protection. This study evaluates the protective efficacy of a 0.12 mmPb leaded acrylic full-face shield through a series of comprehensive in vivo dose measurements conducted on a primary cardiologist during real-time fluoroscopy procedures. The cardiologist was equipped with a tight-fitting elastic mask where 29 small pockets were distributed across the head, housing 29 thermoluminescent dosemeters (TLD) calibrated in Hp(0.07). Two series of measurements were conducted: the first using the leaded acrylic face shield without protective glasses, and the second without the leaded face shield and with protective glasses. The Dose Reduction Factors (DRFs) for the different superficial head areas, calculated as the ratio of Hp(0.07) with and without the leaded face shield, depended on the measurement point as expected and ranged between 0.32 and 0.57, where the lower value was for the frontal lobe. Regarding dose reduction measured around the eye orbit, a DRF of 0.10 and 0.35 was achieved for the right and left sides, respectively, indicating a significant level of protection of the ocular area.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical evaluation of radiation-shielding effects of a head-and-neck X-ray protective device during cardiovascular interventional procedures.Radiological physics and technology · 2026
- Influence of forehead gap size on eye protection provided by lead eyewear worn over prescription glasses: A Monte Carlo studyMedical Physics · 2026
- Evaluation of radiation-protection drapes for reducing operator and patient radiation dose during overtable fluoroscopy: a phantom study.Journal of radiological protection : official journal of the Society for Radiological Protection · 2026
- Occupational radiation exposure and radiation protection practices in interventional radiology and cardiology: A multicenter study in FranceDiagnostic and Interventional Imaging · 2026
- Randomized Evaluation of a Textile-Based Enhanced Radiation Protection Device Versus Control Shielding in the Cardiac Catheterization Laboratory.Journal of the Society for Cardiovascular Angiography & Interventions · 2026
- Impact of Radiation-Attenuating Drape on Exposure in a Contemporary Cardiac Catheterization Laboratory: The ATTENUATE Trial.Journal of the Society for Cardiovascular Angiography & Interventions · 2026