Effect of Electroconvulsive Therapy on Intracranial Pressure: An Evaluation Using Optic Nerve Sheath Diameter Measurements.
Ping Fu, Resheek Nerella, Peter B Rosenquist, Morgan Wan, Vikas Kumar
Department of Trauma and Acute Care Surgery, University of Illinois College of Medicine Peoria, Peoria, IL. · Department of Psychiatry and Health Behavior.
Key points
From the paper's conclusion- These findings strongly suggest that ECT does not induce substantial alterations in intracranial pressure, as determined through ONSD ultrasonography. Nevertheless, it is imperative to underscore the necessity for further research encompassing larger patient cohorts and those who may have baseline elevations of ICP.
Abstract
OBJECTIVES: Electroconvulsive therapy (ECT) stands as a widely acknowledged and effective treatment modality for a range of psychiatric disorders but requires careful patient selection and monitoring to ensure safety in the presence of risk factors given the pronounced physiologic response to the treatment and its attendant generalized anesthesia. Although there is substantial evidence indicating that ECT may trigger an increase in intracranial pressure (ICP) under specific patient circumstances, no studies demonstrate the degree of ICP changes associated with routine clinical ECT. Ultrasonographic measurement of the optic nerve sheath diameter (ONSD) provides an indirect measure of intracranial pressure. METHODS: We conducted serial ONSD assessments in 24 patients at four pivotal junctures during ECT treatment: pre-ECT administration, postanesthesia induction, immediate postictal seizure, and postanesthesia recovery. The ONSD measurements were analyzed with a two-way analysis of variance (ANOVA). RESULTS: We found no statistically significant discrepancies in ONSD measurements compared to baseline readings at any of the post-ECT time points. In addition, there was no difference in ONSD changes between patients who did or did not receive esmolol during treatment or underwent ECT with either unilateral or bilateral electrode placement. CONCLUSIONS: These findings strongly suggest that ECT does not induce substantial alterations in intracranial pressure, as determined through ONSD ultrasonography. Nevertheless, it is imperative to underscore the necessity for further research encompassing larger patient cohorts and those who may have baseline elevations of ICP.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of Ultrasound and Computed Tomography Optic Nerve Sheath Diameter for Intracranial Pressure Assessment in Pediatric Neurocritical Care.Pediatric neurology · 2026
- Optic Nerve Sheath Diameter as a Marker of Elevated Intracranial Pressure in Preeclampsia Compared to Controls.Nigerian journal of clinical practice · 2026
- Ultrasound assessment of the optic nerve sheath diameter in adult patients with suspected intracranial hypertension: A scoping review.Australian critical care : official journal of the Confederation of Australian Critical Care Nurses · 2026
- Ultrasound Measurement of Optic Nerve Sheath Diameter for Detection of Elevated Intracranial Pressure in Pediatric Encephalitis.Annals of Indian Academy of Neurology · 2026
- Limited utility of optic nerve sheath diameter for monitoring intracranial pressure in patients with intracranial hemorrhage.Frontiers in neurology · 2026
- Longitudinal optic nerve sheath diameter trajectories in neurocritical care patients after mechanical thrombectomy or decompressive craniectomy: A descriptive bedside ultrasound study.PloS one · 2026