Ultrasound assessment of the optic nerve sheath diameter in adult patients with suspected intracranial hypertension: A scoping review.
Isabelly Nogueira Ferreira, Gabrielle Brito Lopes, Fernanda Raphael Escobar Gimenes, Vinícius Batista Santos, Wellingson Silva Paiva, Patrícia Rezende do Prado
Ribeirão Preto College of Nursing, University of São Paulo, Ribeirão Preto, SP, Brazil. · Federal University of São Paulo (UNIFESP), São Paulo, SP, Brazil.
Key points
From the paper's conclusion- ONSD is a viable, noninvasive approach for assessing suspected intracranial hypertension; it most commonly employs a high-frequency linear transducer in B-mode. The optic nerve is most consistently measured 3 mm posterior to the globe. However, variability in measurement techniques and cut-off values highlights the need for greater standardisation. Furthermore, the limited number of studies addressing the role of nursing indicates a knowledge gap that must be bridged to integrate ONSD ultrasound into nursing practice. OSF REGISTRATION: https://osf.io/m4ej9/.
Abstract
OBJECTIVES: The aim of this study was to map how the ultrasound measurement of the optic nerve sheath diameter is performed in adults with suspected intracranial hypertension. METHODS: This scoping review was conducted in accordance with the JBI Collaboration and reported following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for scoping review guidelines. Two independent reviewers searched PubMed, Cumulative Index to Nursing and Allied Health Literature (CINAHL), Latin American and Caribbean Health Sciences Literature (LILACS), Nursing Database (BDENF), Cochrane Library, Scopus, Embase, Livivo, Web of Science Core Collection, and the CAPES thesis and dissertation repository. Grey literature included Google Scholar. RESULTS: Of the 2019 records identified, 239 were included. Optic nerve sheath diameter (ONSD) ultrasonography is primarily performed in adults with suspected or at risk of intracranial hypertension, particularly critically ill, neurocritical care, emergency, and trauma patients. Across the included studies, patients were assessed in the supine position, with their eyes closed, using a high-frequency linear transducer in B-mode. The optic nerve is most consistently measured 3 mm posterior to the globe. The included studies showed variability in ONSD cut-off values suggestive of increased intracranial pressure. Lower thresholds, particularly >5.0 mm, showed high sensitivity (99%) but lower specificity (73%), whereas values between 5.6 and 6.3 mm tended to provide greater specificity. Studies assessing diagnostic performance reported favourable results for ONSD ultrasonography; however, heterogeneity in cut-off values, populations, reference standards, and measurement techniques precludes the definition of a universally accepted threshold. CONCLUSION: ONSD is a viable, noninvasive approach for assessing suspected intracranial hypertension; it most commonly employs a high-frequency linear transducer in B-mode. The optic nerve is most consistently measured 3 mm posterior to the globe. However, variability in measurement techniques and cut-off values highlights the need for greater standardisation. Furthermore, the limited number of studies addressing the role of nursing indicates a knowledge gap that must be bridged to integrate ONSD ultrasound into nursing practice. OSF REGISTRATION: https://osf.io/m4ej9/.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- 3-D Ultrasound as a new indicator for Optic Nerve Sheath Volume.Ultrasound in medicine & biology · 2026
- Diagnostic and Prognostic Value of Sonographic Optic Nerve Sheath Diameter in Patients with Ischemic Stroke or Hypertensive Intracerebral Hemorrhage.Neurocritical care · 2026
- Comparison of Ultrasound and Computed Tomography Optic Nerve Sheath Diameter for Intracranial Pressure Assessment in Pediatric Neurocritical Care.Pediatric neurology · 2026
- Derivative indices of optic nerve sheath diameter: a novel ultrasound-based approach for non-invasive intracranial pressure monitoring in neurocritical patients.Frontiers in neurology · 2026
- Limited utility of optic nerve sheath diameter for monitoring intracranial pressure in patients with intracranial hemorrhage.Frontiers in neurology · 2026
- Evaluation of CSF pressures, OCT parameters, and transorbital ultrasonographic measurements in ıdiopathic ıntracranial hypertension.International ophthalmology · 2026