Limited utility of optic nerve sheath diameter for monitoring intracranial pressure in patients with intracranial hemorrhage.
Beschan Ahmad, Mario Maria Joachim Trappe, Lars-Olav Harnisch, Onnen Moerer, Ibrahim Allam, Fabian Kück, Ilko L Maier
Department of Neurology, University Medical Center Göttingen, Göttingen, Germany. · Department of Anesthesiology, University Medical Center Göttingen, Göttingen, Germany.
Key points
From the paper's conclusion- These findings question its reliability as a stand-alone tool for serial monitoring of dynamic ICP changes in treated neurocritical care patients and therefore should not be interpreted as a direct substitute for invasive ICP or as a stand-alone measure of short-term ICP change.
Abstract
INTRODUCTION: Monitoring intracranial pressure (ICP) is a key component in the management of patients with intracranial hemorrhage. Transorbital ultrasound (toUS)- based measurement of the optic nerve sheath diameter (ONSD) - has been proposed as a non-invasive surrogate for ICP assessment. However, substantial variability in measurement techniques and cut-off values has raised concerns regarding its reliability. This study aimed to evaluate the association between repeatedly measured ONSD and invasively measured ICP in patients with intracranial hemorrhage and to assess the ability of ONSD to reflect changes in ICP over time. METHODS: In this prospective longitudinal study ONSD was measured daily using ultrasound at 3- and 6 mm posterior to the optic disc and compared with simultaneously recorded invasive ICP measurements. A total of 55 patients with intracranial hemorrhage were included, contributing repeated measurements over a mean of 5.47 ± 2.27 days. RESULTS: Overall, the association between ICP and ONSD was weak. In the prespecified primary analysis, ICP was not associated with bilateral mean irONSD at 3 mm (β = 0.004 mm per mmHg, 95% CI - 0.003 to 0.011; p = 0.169; marginal R2 = 0.3%). At 6 mm, a small but statistically significant relationship was detectable at bilateral ICP mean values for outer-reflection ONSD [β = 0.010, 95% CI (0.002-0.019), p = 0.016; marginal r2 = 1.3%]. CONCLUSION: ICP explains less than 2% of the variance in ONSD in this treated cohort with predominantly controlled ICP. These findings question its reliability as a stand-alone tool for serial monitoring of dynamic ICP changes in treated neurocritical care patients and therefore should not be interpreted as a direct substitute for invasive ICP or as a stand-alone measure of short-term ICP change.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of Ultrasound and Computed Tomography Optic Nerve Sheath Diameter for Intracranial Pressure Assessment in Pediatric Neurocritical Care.Pediatric neurology · 2026
- Diagnostic and Prognostic Value of Sonographic Optic Nerve Sheath Diameter in Patients with Ischemic Stroke or Hypertensive Intracerebral Hemorrhage.Neurocritical care · 2026
- Derivative indices of optic nerve sheath diameter: a novel ultrasound-based approach for non-invasive intracranial pressure monitoring in neurocritical patients.Frontiers in neurology · 2026
- Ultrasound assessment of the optic nerve sheath diameter in adult patients with suspected intracranial hypertension: A scoping review.Australian critical care : official journal of the Confederation of Australian Critical Care Nurses · 2026
- An Eye on Survival: Association Between Initial Optic Nerve Sheath Diameter and 30-Day Mortality in Patients With Traumatic Brain Injury.Cureus · 2026
- 3-D Ultrasound as a new indicator for Optic Nerve Sheath Volume.Ultrasound in medicine & biology · 2026