Pediatric neurology

Comparison of Ultrasound and Computed Tomography Optic Nerve Sheath Diameter for Intracranial Pressure Assessment in Pediatric Neurocritical Care.

Maricela García-Arellano, Deysi Guadalupe Hernández-Ortiz, Jesús Alonso Gaona-Espejo, Sergio Erik Munguía-Chavez, Juan Manuel Marquez-Romero

Servicio de Terapias Pediátricas, Centenario Hospital "Miguel Hidalgo", Aguascalientes, Aguascalientes, Mexico. · Departamento de Terapia Endovascular Neurológica, Hospital General de Zona #3, OOAD Aguascalientes, Aguascalientes, Aguascalientes, Mexico. Electronic address: scint1st@gmail.com.

Key points

From the paper's conclusion
  • ONSD-US demonstrated an association with invasively measured ICP after accounting for repeated measurements, whereas ONSD-CT did not show a clear association. Weak intermodality correlation suggests that ONSD-US and ONSD-CT should not be considered interchangeable methods for noninvasive ICP assessment in pediatric neurocritical care.

Abstract

BACKGROUND: Noninvasive intracranial pressure (ICP) assessment remains challenging in pediatric neurocritical care. Optic nerve sheath diameter (ONSD) measured by ultrasound (ONSD-US) and computed tomography (ONSD-CT) has been proposed as a surrogate marker of ICP, although comparative pediatric data remain limited. METHODS: Prospective observational study conducted in a tertiary pediatric intensive care unit. Patients requiring invasive ICP monitoring were consecutively included. ONSD-US measurements were obtained simultaneously with invasive ICP measurements and, for patients undergoing CT, within 5 minutes before or after transfer for imaging. Pearson correlation and linear mixed-effects models accounting for repeated measurements were used. Bland-Altman analysis assessed intermodality agreement. RESULTS: Eighteen patients contributed 139 measurement occasions. ONSD-US measurements were available in 116 occasions and ONSD-CT measurements in 37; 14 paired measurements from 11 patients included both modalities. One additional CT-derived measurement was excluded because of inadequate image quality, while the corresponding ONSD-US measurement was retained. ONSD-US showed a positive correlation with ICP (r = 0.32, P < 0.001), whereas ONSD-CT did not demonstrate a significant correlation (r = 0.23, P = 0.17). In mixed-effects analysis, each 1-mm increase in ONSD-US was associated with an estimated 3.24-mmHg increase in ICP (standard error 1.10; 95% confidence interval 1.09-5.39). Correlation between modalities was weak and not statistically significant (r = 0.31, P = 0.29). CONCLUSIONS: ONSD-US demonstrated an association with invasively measured ICP after accounting for repeated measurements, whereas ONSD-CT did not show a clear association. Weak intermodality correlation suggests that ONSD-US and ONSD-CT should not be considered interchangeable methods for noninvasive ICP assessment in pediatric neurocritical care.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers