Ultrasound Measurement of Optic Nerve Sheath Diameter for Detection of Elevated Intracranial Pressure in Pediatric Encephalitis.
Huynh Ngoc Le Duy, Tran Diep Tuan, Tran Thanh Thuc, Nguyen Thi Mai Anh, Phung Nguyen The Nguyen
Department of Infectious Disease Intensive Care Unit, Children's Hospital 1, Ho Chi Minh City, Vietnam. · School of Medicine, University of Medicine and Pharmacy at Ho Chi Minh City, Vietnam.
Key points
From the paper's conclusion- Ultrasound measurement of ONSD is a useful, noninvasive, repeatable bedside tool for early identification of elevated ICP in pediatric encephalitis. Incorporating age-specific ROC-derived ONSD thresholds may improve diagnostic accuracy and support bedside assessment in pediatric intensive care settings.
Abstract
BACKGROUND AND OBJECTIVES: Elevated intracranial pressure (ICP) is a critical and potentially life-threatening complication of pediatric encephalitis. Early detection is essential for improved outcomes. This study assessed the diagnostic utility of optic nerve sheath diameter (ONSD) ultrasound for identifying elevated ICP in children with encephalitis. METHODS: A prospective descriptive case series was conducted at the Infectious Disease Intensive Care Unit (ID-ICU), Children's Hospital 1, Ho Chi Minh City, from August 2023 to April 2025. Children with encephalitis underwent daily ONSD ultrasound during the first seven days of admission. Elevated ICP was defined based on clinical signs and neuroimaging findings. ONSD measurements were compared between patients with and without elevated ICP, and age-specific diagnostic cut-off values were determined. RESULTS: Thirty-six patients were enrolled, with elevated ICP confirmed in 72.2% of cases. ONSD values were higher in patients with raised ICP than in those without at all time points. Receiver operating characteristic (ROC) analysis identified optimal ONSD thresholds for detecting elevated ICP of 5.2 mm in children younger than 60 months, 5.9 mm in those aged 60 months or older, and 5.6 mm in the overall cohort. Serial measurements showed a decline in ONSD over time. No significant difference was observed between right and left eye measurements, with strong inter-eye correlation. CONCLUSIONS: Ultrasound measurement of ONSD is a useful, noninvasive, repeatable bedside tool for early identification of elevated ICP in pediatric encephalitis. Incorporating age-specific ROC-derived ONSD thresholds may improve diagnostic accuracy and support bedside assessment in pediatric intensive care settings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of Ultrasound and Computed Tomography Optic Nerve Sheath Diameter for Intracranial Pressure Assessment in Pediatric Neurocritical Care.Pediatric neurology · 2026
- Derivative indices of optic nerve sheath diameter: a novel ultrasound-based approach for non-invasive intracranial pressure monitoring in neurocritical patients.Frontiers in neurology · 2026
- Diagnostic and Prognostic Value of Sonographic Optic Nerve Sheath Diameter in Patients with Ischemic Stroke or Hypertensive Intracerebral Hemorrhage.Neurocritical care · 2026
- Comparison of emergency department-measured optic nerve sheath diameter according to early neurological outcome in pediatric patients with traumatic brain injury.International journal of emergency medicine · 2026
- Ultrasound assessment of the optic nerve sheath diameter in adult patients with suspected intracranial hypertension: A scoping review.Australian critical care : official journal of the Confederation of Australian Critical Care Nurses · 2026
- Optic Nerve Sheath Diameter as a Marker of Elevated Intracranial Pressure in Preeclampsia Compared to Controls.Nigerian journal of clinical practice · 2026