Optic Nerve Sheath Diameter as a Marker of Elevated Intracranial Pressure in Preeclampsia Compared to Controls.
S Şimşek, I Başkır, T Sağlam, A Oğuz, B Çabuk
Department of Radiology, Gazi Yaşargil Training and Research Hospital, Diyarbakır, Türkiye. · Department of Obstetrics and Gynecology, Acıbadem Eskişehir Hospital, Eskişehir, Türkiye.
Key points
From the paper's conclusion- ONSD is higher in preeclampsia, especially in severe cases. Ocular ultrasound may help with quick screening and follow-up, but confirmation in larger studies using imaging or invasive ICP standards is needed.
Abstract
BACKGROUND: Preeclampsia may be complicated by cerebral edema and elevated intracranial pressure (ICP), yet magnetic resonance imaging is not always feasible for urgent or serial assessment. Ultrasonographic optic nerve sheath diameter (ONSD) measurement is a bedside surrogate that may reflect ICP-related changes. AIM: To compare ONSD values among nonpregnant healthy women, normotensive pregnant women, and women with preeclampsia (with and without severe features), and to evaluate the discriminative performance of ONSD for hypertensive disorders of pregnancy. METHODS: This single-center retrospective cohort study (January 2021-January 2025) included 79 participants: nonpregnant healthy women ( n = 19), normotensive pregnant women ( n = 20), preeclampsia ( n = 20), and severe preeclampsia ( n = 20). Preeclampsia diagnosis/severity followed the American College of Obstetricians and Gynecologists criteria. ONSD was measured by ocular ultrasonography (Voluson S8) 3 mm posterior to the globe in both eyes; the mean of both eyes was analyzed. Measurements were performed contemporaneously by four radiologists and recorded by consensus. RESULTS: Groups were comparable regarding age, gravidity, parity, and gestational week at measurement (mean gestational age 34.20 ± 0.70 weeks; P > 0.05). Mean ONSD increased stepwise across groups: 4.11 ± 0.21 mm (nonpregnant controls), 4.62 ± 0.19 mm (pregnant controls), 5.71 ± 0.18 mm (preeclampsia), and 5.99 ± 0.20 mm (severe preeclampsia) ( P < 0.001). An ONSD cutoff of 5.15 mm distinguished preeclampsia/severe preeclampsia from the control groups with excellent diagnostic performance (AUC = 1.000; P < 0.001). CONCLUSION: ONSD is higher in preeclampsia, especially in severe cases. Ocular ultrasound may help with quick screening and follow-up, but confirmation in larger studies using imaging or invasive ICP standards is needed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Longitudinal Peripartum Assessment of Retinal Nerve Fiber Layer Thickness and Optic Nerve Sheath Diameter in Women with Preeclampsia and Normotensive Pregnant Controls.Journal of clinical medicine · 2026
- Diagnostic and Prognostic Value of Sonographic Optic Nerve Sheath Diameter in Patients with Ischemic Stroke or Hypertensive Intracerebral Hemorrhage.Neurocritical care · 2026
- Comparison of Ultrasound and Computed Tomography Optic Nerve Sheath Diameter for Intracranial Pressure Assessment in Pediatric Neurocritical Care.Pediatric neurology · 2026
- Derivative indices of optic nerve sheath diameter: a novel ultrasound-based approach for non-invasive intracranial pressure monitoring in neurocritical patients.Frontiers in neurology · 2026
- Ultrasound assessment of the optic nerve sheath diameter in adult patients with suspected intracranial hypertension: A scoping review.Australian critical care : official journal of the Confederation of Australian Critical Care Nurses · 2026
- Limited utility of optic nerve sheath diameter for monitoring intracranial pressure in patients with intracranial hemorrhage.Frontiers in neurology · 2026