A-391 Short-term stability of clinical chemistry analytes in serum samples collected using a novel capillary blood collection device

Kaylan Olds, Logan Jeffers, J Poppa, Brian Massie, Evgenia Macke, Spencer Stowell, Sahar Mamdani, Gabrielle War,

Key points

From the paper's conclusion
  • These findings support the feasibility of remote capillary blood collection for many common clinical chemistry tests.

Abstract

Background Capillary blood collection devices offer potential advantages for remote patient monitoring and decentralized clinical trials by enabling specimen collection outside traditional healthcare settings. However, samples collected remotely may experience delays before laboratory processing, making analyte stability a critical consideration. The Tasso+ lancet paired with BD SST microtainer provides a novel, push-button solution to capillary blood collection without requiring fingerstick lancets. Understanding short-term stability of clinical chemistry analytes in these samples is essential to establish appropriate handling and transport requirements for clinical use. Methods Fresh, non-additive venous blood samples were collected from eight volunteers and immediately aliquoted into BD SST Microtainers. Sample aliquots were processed into serum and tested in replicates of 2 or 3 (based on available volume) at baseline (T0) and after storage under two conditions: ambient temperature (15-25°C) at 4 and 4.5 hours and refrigerated (2-8°C) at 48 and 52 hours. Twenty-three clinical chemistry analytes were evaluated: albumin, ALP, ALT, AST, BUN, calcium, chloride, total cholesterol, creatinine, cystatin C, GGT, glucose, HDL cholesterol, high-sensitivity CRP, potassium, LDL cholesterol, lipoprotein(a), sodium, NT-proBNP, total bilirubin, total protein, triglycerides, and bicarbonate (CO2). Testing was performed using a Roche cobas instrument by TriCore Reference Laboratory. Stability was assessed using percent deviation (PD%) from baseline, with acceptance criteria of less than 10%. Results All analytes met acceptance criteria across ambient timepoints (4 and 4.5 hours) and at the refrigerated 48-hour timepoint. At the 52-hour refrigerated timepoint, CO2 and total bilirubin failed to meet acceptance criteria. All other analytes including liver enzymes, lipid panel components, renal function markers, electrolytes, and inflammatory markers maintained acceptable stability throughout the study period under both storage conditions. Additional testing is required to confirm stability for lipoprotein(a) and NT-proBNP due to insufficient sample size (n < 3). Results presented for those two analytes are considered preliminary. Conclusion Clinical chemistry analytes in capillary serum samples collected using the Tasso+ lancet demonstrate acceptable short-term stability for at least 4.5 hours at ambient temperature and 52 hours under refrigeration for the majority of analytes tested. These findings support the feasibility of remote capillary blood collection for many common clinical chemistry tests. Bicarbonate and total bilirubin require refrigerated transport and processing within 48 hours. This stability profile enables practical implementation of capillary collection for wellness screening, chronic disease monitoring, and decentralized clinical trials.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers