A-390 Method comparison of a novel capillary blood collection device for clinical chemistry testing: comparison with venous blood on two automated platforms

Kaylan Olds, J Poppa, Spencer Stowell, Brian Massie, Evgenia Macke, Erwin Berthier, Timothy Bauer

Observational

Key points

From the paper's conclusion
  • These findings support continued development of capillary blood collection as a viable alternative to traditional venipuncture for select clinical chemistry testing.

Abstract

Background Venipuncture remains the standard for blood collection but presents barriers including patient anxiety, need for trained phlebotomists, and limited accessibility for remote testing. Capillary blood collection offers a less invasive alternative that could expand access to laboratory testing. The Tasso+ lancet paired with BD SST microtainer is a novel, push-button solution designed for easy capillary blood collection without fingerstick lancets. This study evaluated the performance of 23 clinical chemistry analytes in Tasso+ capillary serum samples compared to matched venous samples. Methods A prospective, multi-site clinical study was conducted at five US sites with 163 evaluable participants. The study population included adults with diverse demographics and health conditions to promote adequate analyte distribution across clinically relevant ranges. Participants provided paired capillary blood samples collected by healthcare professionals (HCPs) along with venous reference samples obtained via standard venipuncture. Testing was performed within 48 hours of collection (transported under ambient conditions) on Abbott Alinity ci-series and Roche cobas c 503/e 801 analyzers. Twenty-three clinical chemistry analytes were evaluated: albumin, alkaline phosphatase (ALP), alanine aminotransferase (ALT), aspartate aminotransferase (AST), blood urea nitrogen (BUN), calcium, chloride, total cholesterol, creatinine, cystatin C, GGT, glucose, HDL, high-sensitivity C-reactive protein (hsCRP), potassium, LDL, lipoprotein(a), sodium, NT-proBNP, total bilirubin, total protein, triglycerides, and bicarbonate (CO2). Method comparison utilized Deming or Passing-Bablok regression assessment with estimated bias at medical decision points (MDPs). Acceptance criteria were applied to slope (0.95 - 1.05) and R values (at least 0.95) in addition to bias at each MDP (within 50% CLIA 2025). Results for analytes with range limitations which met one out of two regression criteria were considered preliminary. Results Nine analytes met acceptance criteria on both platforms: ALP, ALT, BUN, cholesterol, hsCRP, and lipoprotein(a). GGT and NT-proBNP were only tested on one platform and also met acceptance criteria. AST, and glucose met criteria on one platform with provisional acceptance on the other. Several electrolytes as well as albumin, bilirubin, and triglycerides did not meet acceptance criteria, likely due to sample matrix effects and/or pre-analytical variables (transport/storage time). The safety profile was favorable with a 3.1% adverse event rate (5/163 participants): 4 events were mild and 1 was moderate intensity. All AEs were pre-determined expected reactions that included discomfort, itchiness, or skin marks at the collection site. Conclusion Upper arm capillary collection using Tasso+ devices demonstrates acceptable analytical performance for multiple clinically important analytes when compared to venous blood reference samples. Analytes suitable for capillary testing include liver enzymes, lipids, cardiac biomarkers, renal function markers, and inflammatory biomarkers. The device shows promise for expanding access to laboratory testing through simplified collection, particularly for wellness screening, chronic disease monitoring, and remote healthcare applications. Further optimization may improve performance for electrolytes and other biomarkers. These findings support continued development of capillary blood collection as a viable alternative to traditional venipuncture for select clinical chemistry testing.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers