B-021 Evaluation of Capillary Serum as an Alternative Matrix for Hepatic Function Tests
Sonia La’ulu, Sierra Cunningham, Erik Kish-Trier, Abby Tyler, Joseph Rudolf
Key points
From the paper's conclusion- These findings support capillary serum as a suitable alternative specimen type for hepatic function testing on the Roche cobas pro c503.
Abstract
Background As blood collection modalities expand, evaluation of capillary blood is necessary to assess equivalence to venous blood and verify analytical performance. This study evaluates capillary serum as an alternative matrix for hepatic function tests. Methods The analytical suitability of capillary serum was assessed for hepatic function tests using the Roche cobas pro c503 analyzer for the following analytes: albumin (ALB), alkaline phosphatase (ALKP), alanine aminotransferase (ALT), aspartate aminotransferase (AST), direct bilirubin (DBILI), total bilirubin (TBILI), gamma-glutamyltransferase (GGT), and total protein (TP). Specimens were collected using serum separator tubes (SST; Becton Dickinson), specifically the Microtainer SST for capillary blood collected by the Tasso+ device and the Vacutainer SST for venipuncture. All specimen collections or use of residual specimens followed an Institutional Review Board-approved protocol. Analytical performance was evaluated through paired sample equivalence (capillary vs. venous), whole blood delayed separation stability, post-centrifugation capillary serum stability across multiple storage conditions, and matrix effect characterization via mixing recovery and dilution recovery studies. Acceptance criteria were based on calculated percent differences being within analyte-specific total allowable error (TAE). For mixing and dilution recovery studies, percent recoveries between 80-120% were considered acceptable. Paired capillary and venous samples were collected and compared to evaluate sample equivalency. Delayed separation stability was assessed by storing whole blood at 2-8 °C for 48 and 72 hours before centrifugation. Capillary serum stability was evaluated by storing capillary serum specimens (with no delayed centrifugation) at ambient, refrigerated, and frozen (-20 °C) temperature conditions. To evaluate matrix effect of capillary serum, mixing recovery studies were performed using admixtures of low and high concentration capillary serum (0%, 25%, 50%, 75%, and 100% of the high sample). Dilution recovery studies were performed by manually diluting capillary serum with normal saline (recommended diluent) according to manufacturer specified dilutions and correcting results for the dilution factor to assess recovery accuracy. Results Capillary and venous serum demonstrated agreement within analyte-specific TAE across all analytes, with no systematic bias observed (Figure 1). Delayed separation studies showed acceptable stability through 72 hours of refrigerated storage of whole blood. Capillary serum stability was maintained for 24 hours at ambient temperature and 7 days refrigerated. Frozen stability was acceptable for 2 weeks for all analytes. While most remained stable through 1 month, ALT exceeded TAE at 1 month but was found to be acceptable for 2 weeks. Mixing recovery studies demonstrated linearity with percent recoveries ranging from 100.0-113.6%, indicating no significant matrix effect from capillary serum for these analytes. Dilution recovery studies produced recoveries of 101.4-116.3%, verifying both onboard dilution protocols and no observed matrix effect. Conclusion Collectively, these results indicate that capillary serum matrix does not interfere with accurate analyte measurement for hepatic function tests and is analytically comparable to venous serum. These findings support capillary serum as a suitable alternative specimen type for hepatic function testing on the Roche cobas pro c503. Adoption of capillary serum enables expanded access to testing without compromising analytical accuracy or method robustness.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A-390 Method comparison of a novel capillary blood collection device for clinical chemistry testing: comparison with venous blood on two automated platformsClinical Chemistry · 2026
- A-391 Short-term stability of clinical chemistry analytes in serum samples collected using a novel capillary blood collection deviceClinical Chemistry · 2026
- A-389 Understanding sample-to-sample variability in capillary blood collections: comparison with venous samplingClinical Chemistry · 2026
- Capillary Blood Collection Methods: An assessment of different collections technologies compared to traditional venous sampling.Annals of clinical biochemistry · 2026
- B-295 Comparison of capillary blood to venous blood for use with the Vitamin D Total II assay on the Atellica IM AnalyzerClinical Chemistry · 2026
- Evaluation of an Upper Arm Capillary Blood Collection Device Compared with Venous and Fingerstick Sampling.The journal of applied laboratory medicine · 2026