Influence of decontamination strategies on the bond strength of a universal adhesive bonded to hemostatic agent-contaminated dentin.
Ria Sharma, Rajni Nagpal, Udai Pratap Singh, Garima Tyagi, Megha Nagpal, Sakshi Saumya
Department of Conservative Dentistry and Endodontics, Kothiwal Dental College and Research Centre, Moradabad, Uttar Pradesh, India. · Department of Conservative Dentistry and Endodontics, Kothiwal Dental College and Research Centre, Moradabad, Uttar Pradesh, 244001, India.
Key points
From the paper's conclusion- AlCl3-based hemostatic agent contamination adversely affected bonding performance. Decontamination with NaOCl, phosphoric acid, and CHX effectively restored bond strength and interfacial integrity, whereas water and EDTA were less effective.
Abstract
OBJECTIVES: To evaluate the effect of aluminum chloride (AlCl3)-based hemostatic agent contamination and various decontamination protocols on the shear bond strength (SBS) of a universal adhesive applied in self-etch mode, and to assess resin-dentin interface adaptation using scanning electron microscopy (SEM). MATERIALS AND METHODS: Eighty-four extracted human molars were prepared and randomly assigned to seven groups (n = 12): control, contaminated, and five decontamination groups (water, sodium hypochlorite [NaOCl], chlorhexidine [CHX], phosphoric acid, and ethylenediaminetetraacetic acid [EDTA]). Following contamination and respective surface treatments, Prime & Bond Universal adhesive was applied in self-etch mode. Composite cylinders were bonded to dentin surfaces, and SBS was measured. One specimen from each group was subjected to SEM analysis to evaluate the resin-dentin interface. Data was analyzed using one-way analysis of variance (ANOVA) and Tukey's post hoc test (p < 0.05). RESULTS: Contamination with the hemostatic agent significantly reduced SBS (p < 0.001). Decontamination with NaOCl, phosphoric acid, and CHX restored bond strength to values comparable to the control group (p > 0.05). In contrast, water and EDTA groups showed significantly lower SBS than the control (p < 0.05). SEM analysis supported these findings, demonstrating improved interfacial adaptation in NaOCl, phosphoric acid, and CHX-treated groups. CONCLUSIONS: AlCl3-based hemostatic agent contamination adversely affected bonding performance. Decontamination with NaOCl, phosphoric acid, and CHX effectively restored bond strength and interfacial integrity, whereas water and EDTA were less effective.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Influence of dentin depth and hemostatic contamination on microtensile bond strength of a universal adhesive: Effect of phosphoric acid re-etching as a rescue protocol.Journal of clinical and experimental dentistry · 2026
- Effect of decontamination on bond strength of a universal adhesive to saliva-contaminated dentin.European journal of oral sciences · 2026
- Bonding Performance of a Universal Adhesive to Blood‐ and Blood–Saliva‐Contaminated Mineral Trioxide Aggregate: Effect of Cleaning MethodsClinical and Experimental Dental Research · 2026
- The effect of contamination stage and adhesive strategy on the durability of repair bond strength of blood-saliva contaminated aged composite resin.Odontology · 2026
- Tolerance of universal adhesives to saliva and gingival crevicular fluid contamination of dentin.Dental materials : official publication of the Academy of Dental Materials · 2026
- MDP-based Cleaner Restores the Bond Strength and Chemical Interaction of a Self-adhesive Resin Cement to Blood-contaminated Zirconia.The journal of adhesive dentistry · 2026