Effect of decontamination on bond strength of a universal adhesive to saliva-contaminated dentin.
Susana Joice Mendes Maia, Karlos Eduardo Rodrigues Lima, Juliano Sartori Mendonça, Lidiane Costa de Souza, Vicente de Paulo Aragão Saboia
Federal University of Ceará, Campus Sobral, Sobral, Ceará, Brazil. · Department of Restorative Dentistry, Federal University of Ceará, Fortaleza, Ceará, Brazil.
Key points
From the paper's conclusion- All decontamination procedures were effective in recovering BS for both strategies, except for water rinsing and air drying followed by reetching for EARC1, and water rinsing and air drying for SEC1.
Abstract
This study evaluated decontamination procedures for recovering the bond strength (BS) of a universal adhesive system applied in etch-and-rinse (EAR) and self-etch (SE) modes after salivary contamination. Eighteen groups were evaluated (n = 6) according to adhesive strategy, contamination stage, and decontamination procedure (rinsing and air drying, reetching, and adhesive reapplication). For the EAR strategy, the stages were contamination after acid etching (EARC1); contamination over the adhesive before light curing (EARC2); and after light curing (EARC3). For the SE strategy, the stages were contamination over the adhesive before light curing (SEC1) and after light curing (SEC2). The control groups were uncontaminated. Specimens were restored with composite resin and subjected to microtensile BS testing and fracture pattern analysis after 24 h or 6 months. Data were analyzed using two-way analysis of variance followed by a post hoc test (α = 0.05). Contamination significantly affected BS at all stages (p < 0.05). After 6 months, BS was maintained (p > 0.05) only in the SE strategy. All decontamination procedures were effective in recovering BS for both strategies, except for water rinsing and air drying followed by reetching for EARC1, and water rinsing and air drying for SEC1. Decontamination effectiveness depends on the contamination stage, requiring the correct selection of clinical protocols.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The effect of contamination stage and adhesive strategy on the durability of repair bond strength of blood-saliva contaminated aged composite resin.Odontology · 2026
- Influence of decontamination strategies on the bond strength of a universal adhesive bonded to hemostatic agent-contaminated dentin.Journal of oral biology and craniofacial research · 2026
- Influence of dentin depth and hemostatic contamination on microtensile bond strength of a universal adhesive: Effect of phosphoric acid re-etching as a rescue protocol.Journal of clinical and experimental dentistry · 2026
- Tolerance of universal adhesives to saliva and gingival crevicular fluid contamination of dentin.Dental materials : official publication of the Academy of Dental Materials · 2026
- Bonding Performance of a Universal Adhesive to Blood‐ and Blood–Saliva‐Contaminated Mineral Trioxide Aggregate: Effect of Cleaning MethodsClinical and Experimental Dental Research · 2026
- Effect of Etching Protocols on the Bonding Performance of a HEMA-Free Two-Step Universal Adhesive to Caries-Affected Dentin.The journal of adhesive dentistry · 2026