The journal of adhesive dentistry

MDP-based Cleaner Restores the Bond Strength and Chemical Interaction of a Self-adhesive Resin Cement to Blood-contaminated Zirconia.

Pharsiri Sirirangsee, Kittisak Sanon, Pasiree Thongthai, Janeta Chavanavesh, Irin Chiwasuchin, Junji Tagami

Key points

From the paper's conclusion
  • MDP-based cleaner restored bond strength of self-adhesive resin cement to blood-contaminated zirconia and maintained it after thermocycling. This was accompanied by partial reduction of blood-derived surface contamination and uptake of MDP-derived phosphate onto the zirconia surface, with negligible effect on clean zirconia.

Abstract

PURPOSE: Bonding to zirconia remains challenging because of its polycrystalline structure, and intraoperative blood contamination further compromises resin-zirconia adhesion. 10-methacryloyloxydecyl dihydrogen phosphate (MDP)-based cleaners have been proposed to restore bond strength to contaminated zirconia, but their mechanism and durability under aging remain incompletely characterized. This study evaluated the effect of an MDP-based cleaner on the shear bond strength (SBS) and chemical interaction of a self-adhesive resin cement bonded to clean and blood-contaminated zirconia. METHODS AND MATERIALS: Zirconia discs were air-abraded and allocated to four groups: clean zirconia without pretreatment; clean zirconia treated with MDP-cleaner; blood-contaminated zirconia without pretreatment; and blood-contaminated zirconia treated with MDP-cleaner. Self-adhesive resin cement was bonded to each surface. SBS was measured after 24-h water storage or 5,000 thermocycles (n = 15) and analyzed with three-way ANOVA and Tukey's test (α = 0.05). Surface morphology was evaluated by scanning electron microscopy (SEM), and chemical composition and cement-zirconia interaction were evaluated by X-ray photoelectron spectroscopy (XPS). RESULTS: Blood contamination significantly reduced 24-h SBS (p 0.001), decreasing further after thermocycling (p = 0.004). MDP-cleaner treatment recovered SBS on contaminated zirconia (p 0.001) and maintained stability after thermocycling (p = 0.12). SEM showed no morphological alterations. XPS showed partial reduction of nitrogen-containing blood proteins and a pattern consistent with chemical interactions between MDP-derived phosphate groups and zirconia. CONCLUSION: MDP-based cleaner restored bond strength of self-adhesive resin cement to blood-contaminated zirconia and maintained it after thermocycling. This was accompanied by partial reduction of blood-derived surface contamination and uptake of MDP-derived phosphate onto the zirconia surface, with negligible effect on clean zirconia.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

MDP-based Cleaner Restores the Bond Strength and Chemical Interaction of a Self-adhesive Resin Cement to Blood-contaminated Zirconia — Science Skim