Dental materials : official publication of the Academy of Dental Materials

Tolerance of universal adhesives to saliva and gingival crevicular fluid contamination of dentin.

Suqing Tu, Haotian Dong, Jiawen Liu, Ruizhen Liang, Chen Chen, Haifeng Xie

Department of Endodontics, The Affiliated Stomatological Hospital of Nanjing Medical University, State Key Laboratory Cultivation Base of Research, Prevention and Treatment for Oral Diseases, Jiangsu Province Engineering Research Center of Stomatological Translational Medicine, Nanjing, 210029, China. · Department of Oral Mucosal Diseases, The Affiliated Stomatological Hospital of Nanjing Medical University, State Key Laboratory Cultivation Base of Research, Prevention and Treatment for Oral Diseases, Jiangsu Province Engineering Research Center of Stomatological Translational Medicine, Nanjing, 210029, China.

Key points

From the paper's conclusion
  • Universal-adhesive tolerance was contaminant- and load-dependent. Mild residual contamination had limited effects for some formulations, whereas severe GCF contamination compromised polymerization, interfacial sealing, and long-term bond durability. Residual wetting may persist despite routine moisture control and GCF management; moisture-tolerant adhesives should complement, not replace, strict moisture control and periodontal inflammation management.

Abstract

OBJECTIVES: To evaluate the dentin-bonding durability of universal adhesives under saliva and gingival crevicular fluid (GCF) contamination conditions. METHODS: Forty patients underwent paper-strip assessment of residual GCF wetting at subgingival margins under four GCF-management conditions. In vitro, dentin from 318 extracted sound human third molars was tested with three universal adhesives (SB/SP/AB) under no contamination, mild saliva, mild GCF, or severe GCF contamination. Artificial saliva or human serum (GCF surrogate; 20 μL) was applied; mild groups were blot-dried, whereas severe GCF contamination was left unblotted. Contact angles and degree of conversion (DC; adhesive-contaminant mixtures) were assessed immediately; microtensile bond strength (μTBS), failure mode, nanoleakage, and in situ zymography were assessed after 24 h water storage or aging (6 months water storage plus 15,000 thermocycles). ANOVA or linear mixed-effects models were used (α = 0.05). RESULTS: Periodontal status and GCF-management condition affected paper-strip wetted area (both P < 0.001; interaction P < 0.05). Contamination impaired adhesive spreading and reduced DC (P < 0.05). Contamination condition, aging, and adhesive type affected μTBS (all P < 0.05). Aging increased nanoleakage and interfacial gelatinolytic activity (both P < 0.001), particularly under severe GCF contamination. SP showed comparatively greater stability than SB under contamination, whereas differences between SP and AB were condition-dependent. SIGNIFICANCE: Universal-adhesive tolerance was contaminant- and load-dependent. Mild residual contamination had limited effects for some formulations, whereas severe GCF contamination compromised polymerization, interfacial sealing, and long-term bond durability. Residual wetting may persist despite routine moisture control and GCF management; moisture-tolerant adhesives should complement, not replace, strict moisture control and periodontal inflammation management.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.