Calibration of the NDUSRM series and further measurements of 236U/238U isotopic ratios in the Ewing collection.
Thomas L Bailey, David Lund, Griffin Mulcahy, Alistaer Zhou, Noah Cabanas, John P McDonaugh, Ruchi Rathod, William Von Seeger,
Department of Physics and Astronomy, University of Notre Dame, Notre Dame IN, 46556, United States of America. Electronic address: tbailey3@nd.edu. · Department of Physics and Astronomy, University of Notre Dame, Notre Dame IN, 46556, United States of America.
Key points
From the paper's conclusion- A survey of the 236U/238U ratio of various ores from North American and African mines was conducted with the improved setup, using in house reference standards to quantify the measurements.
Abstract
236U is one of the rarest isotopes of uranium, occurring in ores with an abundance below 1×10-9. Due to a wide variety of geological factors, the 236U content in a given uranium ore body is considered to be a unique "fingerprint" like signature, with applications in nuclear forensics and geophysics. Its low abundance though is only detectable via Accelerator Mass Spectrometry (AMS), capable of measuring 236U/238U ratios below 1×10-11. Improvements to the AMS setup at the University of Notre Dame's Nuclear Science Laboratory, have greatly improved its detection limit, enabling measurements across the entire 236U/238U ratio range found in natural ores. A description of the improvements is presented. A survey of the 236U/238U ratio of various ores from North American and African mines was conducted with the improved setup, using in house reference standards to quantify the measurements. A new detection limit of 1×10-12 was established.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Single particle - MC-ICP-MS for isotopic analysis of uranium particles.Analytical methods : advancing methods and applications · 2026
- Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometryJournal of Radioanalytical and Nuclear Chemistry · 2026
- Measurement of the Isotopic Composition of Uranium in Geological Samples by MC-ICP-MS Using a TOPO-Based Extraction Chromatographic ProtocolAnalytical Chemistry · 2026
- Performance evaluation of MAGIX-UPu software for determination of uranium and plutonium isotopic composition with medium resolution gamma-ray detectors.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Multi-Collector Extreme Ultraviolet Laser Mass Spectrometry (MC-EUV-MS): Using High-Energy Photoionization for High-Spatial-Resolution Isotope Ratio Mapping of Actinide Materials.Analytical chemistry · 2026
- Capsule-Type Hydrothermal Extraction-Coupled NanoESI-MS/MS for Analysis of Uranium Isotope in Sub-milligram Lunar Regolith Samples.Analytical chemistry · 2026