A passive, battery-free flexible metasurface for implantable millimetre-wave radar glucose sensing
Kavya Saravanan, Rohini Ramachandran, Jean Pierre Ndabakuranye, Isabelle Shearer, Gursimran Singh, Bobbi Fleiss, Omid Kavehei, Akram Al-Hourani,
Key points
From the paper's conclusion- We investigated whether a passive, battery-free flexible metasurface, implanted beneath tissue and read by a commercial 60 GHz radar, can track blood glucose levels.
Abstract
Continuous glucose monitors (CGM) break the skin barrier and require periodic sensor replacement. We investigated whether a passive, battery-free flexible metasurface, implanted beneath tissue and read by a commercial 60 GHz radar, can track blood glucose levels. The metasurface contained no electronics or reagents. We fitted a conical helix to the in-phase and quadrature radar signals across the frequency sweep and used its mean radius (the spiral radius) as the glucose-dependent feature. We tested glucose concentrations of 25 to 400 mg/dL in saline solution with and without the metasurface, and 196 to 596 mg/dL of total glucose in porcine whole blood beneath ex vivo porcine tissue and in a murine cadaver model with pulsatile blood flow. The metasurface was essential for achieving a monotonic sensor response; in saline, the coefficient of determination ($R^2$) of a logarithmic fit increased from 0.18 without the metasurface to 0.90 with it. In a murine (rat) cadaver model, the signal's spiral radius increased monotonically with glucose concentration despite pulsatile flow ($R^2$ = 0.91), and this monotonic behavior persisted through up to 6 mm of tissue. Although sensitivity decreased at higher glucose levels, each discrete concentration step remained clearly detectable. These results demonstrate that a shallow, passive implant paired with a commercial radar can effectively track blood glucose without requiring onboard electronics or batteries.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Innovative contactless dual-coupled microwave sensor for non-invasive blood glucose monitoringScientific Reports · 2026
- Machine Learning-Aided Microwave Sensing for Blood Glucose Detection: Data Information Enhancement from Reduced Measurement Set.Biosensors · 2026
- Leaky-Wave Antenna for Non-Invasive Continuous Glucose MonitoringarXiv · 2026
- Augmenting ultrasound for continuous glucose monitoring via a wearable acoustically readable microneedle patchScience Advances · 2026
- Association of Mid-Infrared Optoacoustic Sensing with Glucose Dynamics in HumansmedRxiv · 2026
- A Dual-Form Spiral-like Microwave Sensor for Non-Invasive Glucose Monitoring: From Planar Design to Wearable ImplementationElectronics · 2026