A Dual-Form Spiral-like Microwave Sensor for Non-Invasive Glucose Monitoring: From Planar Design to Wearable Implementation
Zaid A. Abdul Hassain, Malik Jasim Farhan, Taha A. Elwi
Mustansiriyah University · Nahrain University
Key points
From the paper's conclusion- The clear correlation between reflection magnitude and glucose level (with R > 0.99) confirms the sensor’s potential as a passive, multiband, and non-invasive glucose monitoring platform.
Abstract
In this paper, a novel multiband microwave resonator is proposed and investigated for non-invasive glucose sensing applications. The structure is based on a compact, planar spiral-like geometry fed by a Coplanar waveguide (CPW) transmission line, designed to support multiple resonant modes through nested concentric rings. A full electromagnetic model was developed to predict the resonance behavior analytically, achieving excellent agreement with Computer Simulated Technology (CST) simulations across four resonant frequencies (2.7, 6.44, 8.0, and 12.8 GHz). The sensor demonstrated high glucose sensitivity at multiple frequencies, with peak values reaching 0.05 dB/mg/dL and 0.038 dB/mg/dL at 10.1 GHz and 6.22 GHz, respectively. To enhance conformability and skin contact, the antenna was further transformed into a semi-cylindrical flexible form suitable for finger-wrapping. Despite the mechanical deformation, the structure preserved its resonance while offering enhanced near-field interaction with biological tissues. The folded sensor achieved a sensitivity of 0.032 dB/mg/dL at 5.25 GHz and a peak gain of 6.05 dB, validating its robustness for wearable deployment. The clear correlation between reflection magnitude and glucose level (with R > 0.99) confirms the sensor’s potential as a passive, multiband, and non-invasive glucose monitoring platform. The physics-informed residual deep learning framework significantly enhances prediction accuracy, achieving an RMSE of 0.28 mg/dL, MARD of 0.13%, and confining 100% of both training and holdout predictions within the <5% ISO-like risk region, thereby ensuring robust and clinically reliable non-invasive glucose estimation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Experimental and Physics-Informed Deep-Learning-Enhanced Wearable Microwave Sensor for Non-Invasive Blood Glucose MonitoringElectronics · 2025
- Innovative contactless dual-coupled microwave sensor for non-invasive blood glucose monitoringScientific Reports · 2026
- A Multifrequency Millimeter-Wave CMOS Sensor for Non-Invasive Continuous Glucose Monitoring Using UMC 0.18 μm Technology.Biosensors · 2026
- High-Sensitivity Non-Invasive Microwave Glucose Sensor with ZnO/CNT Composite Optimized by Deep Learning for Wearable Medical Devices.ACS omega · 2026
- Design of an Ultra-Sensitive Multi-Resonant Moore Fractal SRR Microwave Sensor for Non-Invasive Blood Glucose MonitoringSensors · 2026
- Development and experimental evaluation of single-port substrate integrated waveguide resonator with dual-parameter sensitivity for non-invasive blood glucose monitoringMeasurement · 2026