Innovative contactless dual-coupled microwave sensor for non-invasive blood glucose monitoring
R. A. Elgeddawy, A. S. Abd El-Hameed, A. R. Eldamak, H. M. Elhenawy
Key points
From the paper's conclusion- These results demonstrate the effectiveness of the proposed sensor and indicate the feasibility of sensitive contactless glucose monitoring using a microwave-based sensor.
Abstract
In this paper, a novel non-invasive blood glucose monitoring system based on microwave sensing using a compact, contactless and sensitive dual-coupled sensor configuration is proposed. The proposed sensor consists of two electromagnetically coupled resonators, configured as a bandpass filter centered around 2.2 GHz. The sensor is fabricated on a 40 × 40 mm 2 Rogers RO3003C substrate with a 20 mm gap between the resonators to accommodate different finger sizes and incorporates a dedicated mechanical isolation structure to minimize measurement variability caused by direct contact, applied pressure, and positioning uncertainty. The operation of the sensor is based on near-field electromagnetic coupling between the resonators and biological tissue, enabling detection of glucose-correlated variations in dielectric properties without direct skin contact. The experimental trials for glucose concentrations from 76 to 201 mg/dL showed a monotonic decrease in the transmission coefficient with increasing glucose concentration with a sensitivity of 0.031 dB/mg/dL and frequency shift sensitivity of 0.41 MHz/mg/dL. These results demonstrate the effectiveness of the proposed sensor and indicate the feasibility of sensitive contactless glucose monitoring using a microwave-based sensor.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Multifrequency Millimeter-Wave CMOS Sensor for Non-Invasive Continuous Glucose Monitoring Using UMC 0.18 μm Technology.Biosensors · 2026
- A Dual-Form Spiral-like Microwave Sensor for Non-Invasive Glucose Monitoring: From Planar Design to Wearable ImplementationElectronics · 2026
- Machine Learning-Aided Microwave Sensing for Blood Glucose Detection: Data Information Enhancement from Reduced Measurement Set.Biosensors · 2026
- High-Sensitivity Non-Invasive Microwave Glucose Sensor with ZnO/CNT Composite Optimized by Deep Learning for Wearable Medical Devices.ACS omega · 2026
- Leaky-Wave Antenna for Non-Invasive Continuous Glucose MonitoringarXiv · 2026
- A passive, battery-free flexible metasurface for implantable millimetre-wave radar glucose sensingarXiv · 2026