Augmenting ultrasound for continuous glucose monitoring via a wearable acoustically readable microneedle patch
Wanglinhan Zhang, Jiangang Xu, Xinjia Li, Yeji Jang, Qiqi Liu, Weixin Ma, Guojie Luo, Ming Ma,
Hong Kong Polytechnic University · Shenzhen Institutes of Advanced Technology
Key points
From the paper's conclusion- We introduce an enzyme-free, wearable acoustically readable microneedle patch (ARMPatch) composed of glucose-responsive hydrogel.
Abstract
Continuous glucose monitoring (CGM) represents substantial advancement, yet poses a challenge in wearable health care development. Current enzymatic CGM faces limitations in stability, cost, and durability. We introduce an enzyme-free, wearable acoustically readable microneedle patch (ARMPatch) composed of glucose-responsive hydrogel. Positioned between a standard ultrasound probe and the skin, ARMPatch acts as an acoustic interface enabling CGM using conventional ultrasound. Its hydrogel microneedles minimally penetrate the epidermis, allowing interstitial fluid to trigger variable swelling of the microneedles in response to glucose fluctuations. ARMPatch delivers stable and selective glucose readings for up to 56 days. Glucose variations with millimolar resolution are obtained via ultrasound within a response time of 30 to 60 minutes. In vivo CGM in animal models for 7 days reveals a reversible correlation between microneedle swelling and glucose variations. Acting as "accessory" for standard ultrasound probes, this approach offers a minimally invasive, cost-effective, and long-lasting solution to non-enzymatic CGM, expanding the utility of ultrasound in wearable biosensing.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Hydrogel microneedle patch for low-cost, colorimetric, continuous glucose monitoring.bioRxiv : the preprint server for biology · 2026
- A flexible wireless skin patch for synchronized glucose monitoring and regulationMicrosystems & Nanoengineering · 2026
- Single-use microneedle biosensor for detecting clinically relevant glucose in interstitial fluidBiosensors and Bioelectronics · 2026
- Regenerable, closed-loop, nonenzymatic continuous glucose monitoring enabled by in situ electrochemical interfacial alkalinization.Nature communications · 2026
- A Modular, Bubble-Infused, Hydrogel Ultrasound Wearable for Minimally Invasive Biochemical Monitoring.ACS sensors · 2026
- A wearable paper-based SGR/MCC microneedle array sensor for continuous glucose monitoringMicrosystems & Nanoengineering · 2026