Association of Mid-Infrared Optoacoustic Sensing with Glucose Dynamics in Humans
A. Prebeck, M. Gotsch, F. Gasparin, L. Englert, U. Stahl, V. Ntziachristos
Key points
From the paper's conclusion- These results support MiROS as a promising framework pointing to a sensor with potential for non-invasive glucose sensing in humans, in the future, and a potential step toward less burdensome glucose monitoring for diabetes management.
Abstract
Despite transformative advances in continuous glucose monitoring, current continuous glucose monitoring (CGM) still relies on transcutaneous needle-based sensors that measure glucose in the interstitial fluid, which lags behind blood glucose. Mid-infrared optoacoustic sensing (MiROS) has recently demonstrated a sensitivity to glucose changes of a few tens of mg/dL in mice using non-invasive measurements. However, the relation of MiROS to human measurements remains unknown. We conducted a MiROS pilot study in 30 healthy participants undergoing oral glucose tolerance tests and investigated how optoacoustic signals reflect tissue optical-property variations associated with changes in blood glucose concentration. We defined the Optoacoustic Mid-infrared Signal (OMS) as a readout of glucose-induced alterations in tissue optical properties and compared it with reference blood glucose measurements. The OMS corresponded to a mean absolute error (MAE) of 11.9 mg/dL and a mean absolute percentage error (MAPE) of 10% relative to the reference blood analysis. More than 99.9% of paired OMS values were located in zones A and B of the consensus error grid. The study further showed that OMS compared favourably with concurrently acquired CGM measurements, which showed an MAE of 15.7 mg/dL and a MAPE of 12% and exhibited an average time lag of 10.5 min relative to blood glucose. No comparable lag was observed for the OMS. These results support MiROS as a promising framework pointing to a sensor with potential for non-invasive glucose sensing in humans, in the future, and a potential step toward less burdensome glucose monitoring for diabetes management.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical validation of noninvasive blood glucose measurements by midinfrared spectroscopyCommunications Medicine · 2025
- Non-invasive blood glucose detection system using combined visible and near-infrared spectral dataScientific Reports · 2026
- Non-Invasive Blood Glucose Monitoring Using Machine Learning and Optical Approaches: A Systematic Literature Review and a Proposed Framework for Reproducible and Clinically Reliable Research.Sensors (Basel, Switzerland) · 2026
- Literature-Grounded Simulation of Non-Invasive Glucose Monitoring Using NIR Wearable Sensor Archetypes: Accuracy Metrics, Candidate Confounders, and an Adaptive Calibration Framework.Sensors (Basel, Switzerland) · 2026
- A passive, battery-free flexible metasurface for implantable millimetre-wave radar glucose sensingarXiv · 2026
- How to Demonstrate the Glucose Specificity of a Non-Invasive CGM: A Case Study of the SKAMo-2 Clinical Trial and Neogly™medRxiv · 2026