Comparison of extended kV-CBCT image quality between conventional and O-ring linear accelerators.
Szilvia Gazdag-Hegyesi, Ádám Gáldi, Tibor Major, Csilla Pesznyák
Center of Radiotherapy, National Institute of Oncology, Budapest, Hungary.
Key points
From the paper's conclusion- Our results show that the longitudinal extension does not affect image linearity, making extended CBCT protocols suitable for long target volumes. CBCT-based adaptation may be unsuitable for large lateral or peripheral tumours due to poor image quality. Consequently, the generation of synthetic CTs from peripheral regions of CBCT images should be approached with caution.
Abstract
BACKGROUND: In cases of non-central or large tumours, the use of an extended field of view is important for patient positioning or adaptive treatment. The aim of our study was to investigate the longitudinal and lateral consistency of extended kilovoltage cone-beam CT (kV-CBCT) image quality over the entire scan length. MATERIALS AND METHODS: The study compared extended kV-CBCT image quality between conventional and O-ring linear accelerators (LINACs) using image quality phantoms. The impact of lateral and longitudinal phantom offsets was analysed across the reconstruction algorithms [filtered back projection - Feldkamp-Davis-Kress (FDK) and iterative cone-beam computed tomography (iCBCT)] and imaging protocols. RESULTS: The CT calibration curves showed consistent alignment across LINACs, imaging protocols, longitudinal displacements, and reconstruction algorithms. The average mean difference in the CT numbers measured during longitudinal shifts, averaged over the other material inserts, was 37 ± 15 Hounsfield units (HU). In the homogeneity examination, the lateral inserts displayed signal reductions as they moved away from the isocentre. For an imaging protocol on a ring accelerator, the central insert remained near 8 HU, while the signal of lateral inserts located 20 cm from the isocentre decreased from 0 HU to -160 HU. CONCLUSIONS: Our results show that the longitudinal extension does not affect image linearity, making extended CBCT protocols suitable for long target volumes. CBCT-based adaptation may be unsuitable for large lateral or peripheral tumours due to poor image quality. Consequently, the generation of synthetic CTs from peripheral regions of CBCT images should be approached with caution.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Technical benchmark of a high-speed ring gantry kV-CBCT imager for CBCT-based dose calculation.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026
- Development of a pragmatic methodology for measurement of dose for KV CBCT in radiotherapy: A pilot study.Annals of the ICRP · 2026
- Towards adaptive radiotherapy: Comparing HyperSight and standard CBCT reconstructions on a C-Arm Linac.Journal of applied clinical medical physics · 2026
- Toward Indication-Stratified Local Reference Levels for IGRT Cone-Beam CT: A Clinical Audit of CTDIvol and DLP Across Ten Workflows on Versa HD.Health physics · 2026
- Preliminary evidence of systematic longitudinal offsets in couch corrections associated with CT localizer scan-line placement in head-and-neck image-guided radiotherapy: a brief research report.Frontiers in medicine · 2026
- Evaluation of registration accuracy using short-arc cone-beam computed tomography for image-guided radiotherapy in breast cancer.Journal of applied clinical medical physics · 2026