A Simple Home-based Ring Test May Promote Early Diagnosis of Retinal Detachment, Retinal Vascular Diseases and Common Optic Nerve Disease.
Fuxiang Zhang, Lisa B Arbisser, Abdualrahman Hamad, Jennifer I Lim, Xihui Lin, Gordon Jacobsen, Judy E Kim
Department of Ophthalmology, Henry Ford Health. · John A. Moran Eye Center, University of Utah, Salt Lake City, Utah.
Key points
From the paper's conclusion- Concordance between ring test defects and HVF defects was high, with strong sensitivity and specificity for detecting mid-to-peripheral visual field defects in rhegmatogenous retinal detachment, retinal vascular occlusions, and certain optic neuropathies. Preliminary results of this initial proof-of-concept study suggest that the ring test has potential utility as a home-based screening tool to facilitate earlier awareness of vision-threatening conditions. Further studies are needed to evaluate its role in routine clinical practice.
Abstract
BACKGROUND AND OBJECTIVE: The purpose of this study was to evaluate a simple ring-based visual field screening test to determine whether, when used at home, the findings were similar to clinical evaluation in terms of visual field defects associated with retinal and optic nerve diseases. PATIENTS AND METHODS: This was a prospective observational cross-sectional diagnostic accuracy study. Consecutive patients presenting between May 2023 and February 2025 with acute vision loss, known history of retinal or optic nerve disorders, or symptoms of acute posterior vitreous detachment or floaters were enrolled. A total of 594 patients (667 eyes) were included. With the fellow eye occluded, patients viewed a 360° ring target and reported any missing or distorted segments. Ring-test findings were compared with clinical reference standards including dilated fundus examination, fundus photography, and Humphrey Visual Field (HVF) testing. Concordance between ring test defects and HVF defects was assessed based on location and orientation. RESULTS: Of a total of 667 eyes, 240 eyes underwent HVF testing. Among 88 eyes with HVF defects, the ring test identified 80 (sensitivity, 0.91; 95% CI, 0.83-0.96). Among 152 eyes without HVF defects, 149 were correctly classified (specificity, 0.98; 95% CI, 0.94-1.00). Ring test findings demonstrated strong spatial concordance with clinical pathology. CONCLUSIONS: Concordance between ring test defects and HVF defects was high, with strong sensitivity and specificity for detecting mid-to-peripheral visual field defects in rhegmatogenous retinal detachment, retinal vascular occlusions, and certain optic neuropathies. Preliminary results of this initial proof-of-concept study suggest that the ring test has potential utility as a home-based screening tool to facilitate earlier awareness of vision-threatening conditions. Further studies are needed to evaluate its role in routine clinical practice.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Rapid, Non-Contact, Objective Multifocal Assessment of Visual Function in Glaucoma.Bioengineering (Basel, Switzerland) · 2026
- The TsiogkaSpaeth grid in Indian patients with primary open-angle glaucoma: A cross-sectional diagnostic accuracy study.Indian journal of ophthalmology · 2026
- Assessing Visual Field Defects in Glaucoma Using the Perceptive Scotoma Finder.Korean journal of ophthalmology : KJO · 2026
- A Pilot Study to Compare a Portable Tablet Perimeter with Humphrey Field Analyzer in Patients with Neuro-Ophthalmic Disorders.Journal of binocular vision and ocular motility · 2026
- Evaluation of the Perimouse Online Suprathreshold Visual Field Test for Glaucoma Screening in a Chinese Population: A Comparison with the Humphrey Field Analyzer.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Automated perimetry in pediatric neuro-ophthalmic conditions: virtual reality-based vs. standard tabletop platforms.American journal of ophthalmology · 2026