Automated perimetry in pediatric neuro-ophthalmic conditions: virtual reality-based vs. standard tabletop platforms.
Jeffrey Liu, Nikita Piryani, Zara Saleem, Rizul Naithani, Sharon F Freedman, Bo Wang, Mays A El-Dairi
Department of Ophthalmology, Duke University Medical Center, 2351 Erwin Road, Durham, NC 27710. · Department of Ophthalmology, Duke University Medical Center, 2351 Erwin Road, Durham, NC 27710; Wilmer Eye Institute, Johns Hopkins Hospital, 600 North Wolfe Street, Baltimore, MD 21287.
Key points
From the paper's conclusion- VRF (HVF-equivalent algorithm) testing showed moderate to good concordance with tabletop HVF testing in pediatric neuro-ophthalmic patients, with shorter testing duration and high patient preference, supporting its potential clinical value.
Abstract
OBJECTIVE: The game-based virtual reality field (VRF) testing algorithm has shown promise in pediatric neuro-ophthalmic patients, but the faster Humphrey visual field (HVF) equivalent algorithm has not been studied in this population. The purpose of this study was to compare testing outcomes between tabletop HVF and VRF (HVF-equivalent algorithm) in a pediatric neuro-ophthalmic population. DESIGN: Prospective comparison of diagnostic perimetry testing modalities. PARTICIPANTS: Children (<18 years of age) with a known or suspected neuro-ophthalmic condition. METHODS: Consecutive pediatric patients presenting to one neuro-ophthalmic clinic between January 2025 and April 2026 had clinically indicated visual field testing first with tabletop HVF testing (24-2, Size III, SITA Fast) and then VRF in the HVF-equivalent algorithm (24-2, Size III, AVA Fast). Global parameters, field defect agreement via masked grading, and point-by-point agreement (including total deviation [TD] and pattern deviation [PD] plots) between modalities were evaluated. HVFs with false-negative/false-positive rates >35% or fixation losses >50% were considered unreliable, applying less stringent reliability criteria for this pediatric population. MAIN OUTCOME MEASURES: Agreement rate between HVF and VRF in both defect detection by region (quadrants, and center) and individual plot points (<0.5% probability defect threshold). Comparisons across patient characteristics, perimetry results, and testing modality (HVF vs. VRF). RESULTS: One hundred fourteen patients (210 eyes; mean age 11.4 ± 3.6 years) were enrolled. Ninety-two children (168 eyes) completed both HVF and VRF testing, including 128 reliable and 40 unreliable HVF examinations. Regional defect agreement between HVF and VRF was 65.9% on average, while point-by-point agreement rates for TD and PD plots were 76.6% and 83.7%, respectively. Moderate positive associations were observed between HVF and VRF for mean deviation (R2M = .398, P < .001) and pattern standard deviation (R2M = .576, P < .001). VRF was significantly faster than HVF (2.1 ± 0.17 minutes vs 4.4 ± 1.2 minutes; P < .001) and most queried patients (51/53; 96.2%) preferred VRF to HVF testing. CONCLUSION: VRF (HVF-equivalent algorithm) testing showed moderate to good concordance with tabletop HVF testing in pediatric neuro-ophthalmic patients, with shorter testing duration and high patient preference, supporting its potential clinical value.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Pilot Study to Compare a Portable Tablet Perimeter with Humphrey Field Analyzer in Patients with Neuro-Ophthalmic Disorders.Journal of binocular vision and ocular motility · 2026
- Use of a Virtual Reality Visual Field Device to Improve Quality of Care in the Emergency Department and Inpatient Setting.Journal of neuro-ophthalmology : the official journal of the North American Neuro-Ophthalmology Society · 2026
- Evaluation of the Perimouse Online Suprathreshold Visual Field Test for Glaucoma Screening in a Chinese Population: A Comparison with the Humphrey Field Analyzer.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Natural interaction based visual field prediction in virtual reality - a pilot studymedRxiv · 2026
- Diagnostic yield of Humphrey visual field 30-2 testing for neurological versus non-neurological visual disorders: A tertiary-care retrospective study.Indian journal of ophthalmology · 2026
- Objective Comparison of Commercially Available Virtual Reality Perimetry Devices: a cross-sectional descriptive study.Research square · 2026