Rapid, Non-Contact, Objective Multifocal Assessment of Visual Function in Glaucoma.
Bhim B Rai, Corinne F Carle, Joshua P van Kleef, Emilie M F Rohan, Faran Sabeti, Andrew White, Rohan W Essex, Ted Maddess
John Curtin School of Medical Research, Australian National University, Canberra, ACT 2601, Australia. · Ophthalmology, Westmead Hospital, University of Sydney, Sydney, NSW 2145, Australia.
Key points
From the paper's conclusion- We compared a rapid fifth-generation (5G) objectiveFIELD Analyser® (OFA®) test with two fourth-generation (4G) 8 min tests in the assessment of glaucoma.
Abstract
We compared a rapid fifth-generation (5G) objectiveFIELD Analyser® (OFA®) test with two fourth-generation (4G) 8 min tests in the assessment of glaucoma. We assessed the relative diagnostic power of these three OFA tests, namely two high-resolution 4G tests (wide-field OFA30 and macular OFA15), and a new 5G 90 s test (wide-field OFA30-20). Glaucomatous eyes were classified into mild, moderate, and severe based upon the Matrix 24-2 perimetry Mean Defect (MD). Diagnostic power was estimated by Area Under the Curve of Receiver Operating Characteristic plots (AUROC) and standardised effect sizes (Hedge's g) for each category of glaucoma severity. We tested 37 glaucoma patients (11 females) aged 70.5 ± 9.19 years. Their average Matrix MD was -7.71 ± 6.35 dB. Age-matched normal controls were acquired for the 4G and 5G tests. Per-region sensitivities outperformed per-region response delays. For severe eyes, the OFA30-20 produced an AUROC of 89.7 ± 3.30, which was not significantly different to the OFA30 and OFA15. Hedge's g was ≥2.45 for all those comparisons. We examined the agreement of the MD and Pattern Standard Deviations (PSD) of the two wide-field (OFA30 and OFA30-20) tests. The significant correlations for the sensitivity and delay MDs were >0.85, and for PSDs 0.53 and 0.69. The rapid 5G OFA30-20 test was comparable to the 8 min tests. It therefore may be highly useful for younger people and infirm persons who cannot tolerate longer tests.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of the Melbourne rapid fields-web device-independent online perimeter and the octopus 600 perimeter in glaucoma patients.Frontiers in ophthalmology · 2026
- Agreement, Reliability, and Feasibility of Melbourne Rapid Fields Tablet Perimetry Compared with Humphrey Field Analyzer in Glaucoma.Diagnostics (Basel, Switzerland) · 2026
- Time-Efficient Visual Field Testing Using the Imo Visual Function Analyzer in Glaucoma.Journal of glaucoma · 2026
- Improved Estimation of Rates of Glaucoma Progression Using Spatial Two-Fold Linear Mixed Models.Journal of statistical theory and applications : JSTA · 2026
- Diagnostic accuracy and reliability of portable visual field-testing devices for detecting manifest glaucomatous visual-field loss: a systematic review and meta-analysis.BMC ophthalmology · 2026
- The TsiogkaSpaeth grid in Indian patients with primary open-angle glaucoma: A cross-sectional diagnostic accuracy study.Indian journal of ophthalmology · 2026