Mechanical and Hemodynamic Effects of Balloon-Expandable and Self-Expanding Stents in a Saccular Abdominal Aortic Aneurysm Model: Fluid-Structure Interaction Analyses.
Masanori Murakami, Fei Jiang, Tatsuo Yamashita, Shinsuke Mochizuki
Department of Cardiovascular Surgery, National Hospital Organization Kanmon Medical Center, Shimonoseki, Yamaguchi, Japan. · Department of Mechanical Engineering, Graduate School of Sciences and Technology for Innovation, Yamaguchi University, Ube, Yamaguchi, Japan.
Key points
From the paper's conclusion- Balloon-expandable and self-expanding stents exhibited different effects on vessel wall mechanics and hemodynamics. The findings indicate the importance of evaluating both hemodynamic and mechanical effects when assessing stent-vessel interactions.
Abstract
OBJECTIVES: The aim of this study was to compare the effects of balloon-expandable and self-expanding stents on vessel wall mechanics and hemodynamics in a patient-specific saccular abdominal aortic aneurysm model. METHODS: A patient-specific aneurysm model was constructed using computed tomography images, and balloon-expandable and self-expanding stent models were created. Aortic wall stress was evaluated by contact analysis. Fluid-structure interaction analyses were performed at 5 representative phases selected from the cardiac cycle. Mean intra-aneurysmal flow velocity, wall shear stress (WSS), pressure loss, and energy loss were compared. RESULTS: The balloon-expandable stent produced greater localized aortic wall stress than the self-expanding stent, whereas wall stress was more uniformly distributed with the self-expanding stent. Both stents reduced the mean intra-aneurysmal flow velocity, WSS, pressure loss, and energy loss compared with the no-stent model. However, greater reductions in WSS, pressure loss, and energy loss were noted with the balloon-expandable stent than with the self-expanding stent. CONCLUSIONS: Balloon-expandable and self-expanding stents exhibited different effects on vessel wall mechanics and hemodynamics. The findings indicate the importance of evaluating both hemodynamic and mechanical effects when assessing stent-vessel interactions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Patient-specific hemodynamic evaluation of fenestrated physician-modified endografts in complex abdominal aortic aneurysmsFrontiers in Physics · 2026
- Multi-Objective Structural Optimization of Vascular Stents With Varied Materials Based on Numerical Simulation.International journal for numerical methods in biomedical engineering · 2026
- Impact of Bridging Stent Flaring Angle on Hemodynamic Performance-In Vitro Analysis.Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2026
- Numerical modelling of a vascular palpation device for assessing intracranial aneurysm wall mechanics under heterogeneous conditions.Clinical biomechanics (Bristol, Avon) · 2026
- Hemodynamic-Structural Multi-Fidelity Assessment of Endovascular Flow Diversion Strategies for Cerebral Aneurysm Treatment: An Integrated Computational and Experimental FrameworkbioRxiv · 2026
- Finite Element Investigation of the Influence of Strut Diameter on the Mechanical Performance of Balloon-Expandable Biodegradable PLA/PDO Coronary Stents.Polymers · 2026